FFT ANALYZER AS A SOUND-INTENSITY MEASURING UNIT.

被引:0
|
作者
Ozawa, Kazutoshi [1 ]
机构
[1] Ono Sokki Co, Jpn, Ono Sokki Co, Jpn
来源
JEE. Journal of electronic engineering | 1987年 / 24卷 / 242期
关键词
ACOUSTIC VARIABLES MEASUREMENT - Intensity - MATHEMATICAL TRANSFORMATIONS - Fast Fourier Transforms - ROBOTICS - SIGNAL PROCESSING - Digital Techniques - SPECTRUM ANALYZERS;
D O I
暂无
中图分类号
学科分类号
摘要
SI (Sound Intensity) measurement using the two-microphone method is still a young technology but it offers great possibilities in the area of sound-intensity analysis, particularly for sound sources with complex shapes. This report describes the characteristics, performance and technological problems of sound-intensity analyzing equipment by using Ono Sokki's dual-channel FFT analyzer CF-900 as an example.
引用
收藏
页码:70 / 72
相关论文
共 50 条
  • [41] SIMULATION OF THE LIMITATIONS INDUCED WHEN MEASURING SOUND POWER VIA ACTIVE SOUND INTENSITY
    NICHOLAS, J
    LEMIRE, G
    NOISE CONTROL ENGINEERING JOURNAL, 1984, 23 (03) : 129 - 130
  • [42] Error analysis and calibration for underwater sound intensity measuring system
    HE Zuoyong HE Yuanan SHANG Dejiang (Institute of Underwater Acoustics
    Chinese Journal of Acoustics, 2000, (03) : 193 - 206
  • [43] INFLUENCE OF BACKGROUND NOISE ON SOUND POWER DETERMINATION BY MEASURING SOUND INTENSITY IN DIFFERENT ENVIRONMENTS.
    Tandon, N.
    Acoustics Australia, 1988, 16 (02) : 57 - 58
  • [45] A sound intensity probe for measuring from 50 Hz to 10 kHz
    Jacobsen, F
    Cutanda, V
    Juhl, PM
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 3357 - 3362
  • [46] The effect of horns of short lengths on the intensity of sound from a telephone unit
    Steele, BL
    PHYSICAL REVIEW, 1928, 31 (03): : 0482 - 0487
  • [47] Validity of Research-Grade Actigraphy Unit for Measuring Exercise Intensity
    Han, Ke-Tsung
    Wang, Po-Ching
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (05):
  • [48] Investigation of a system for underwater sound intensity measurement, their calibration and analysis of measuring error
    He, Zuoyoung
    He, Yuanan
    Shang, Dejiang
    Shengxue Xuebao/Acta Acustica, 2000, 25 (03): : 235 - 241
  • [49] Measuring the in-situ airborne sound insulation using the acoustic intensity technique
    Nightingale, T.R.T.
    Halliwell, R.E.
    Canadian Acoustics - Acoustique Canadienne, 1999, 27 (03): : 56 - 57
  • [50] MEASURING FAMILY AND PATIENT SATISFACTION IN THE INTENSIVE CARE UNIT. DOES A CORRELATION EXIST BETWEEN THE ANSWERS OF THE RELATIVES AND THE ANWERS OF PATIENTS?
    Pena, Holanda
    Walkman, R.
    Dominguez Artiga, M. J.
    Ots Ruiz, E.
    Garcia Miguelez, A.
    Ortiz Melon, F.
    Castellanos Ortega, A.
    INTENSIVE CARE MEDICINE, 2012, 38 : S12 - S12