FFT ANALYZER AS A SOUND-INTENSITY MEASURING UNIT.

被引:0
|
作者
Ozawa, Kazutoshi [1 ]
机构
[1] Ono Sokki Co, Jpn, Ono Sokki Co, Jpn
来源
JEE. Journal of electronic engineering | 1987年 / 24卷 / 242期
关键词
ACOUSTIC VARIABLES MEASUREMENT - Intensity - MATHEMATICAL TRANSFORMATIONS - Fast Fourier Transforms - ROBOTICS - SIGNAL PROCESSING - Digital Techniques - SPECTRUM ANALYZERS;
D O I
暂无
中图分类号
学科分类号
摘要
SI (Sound Intensity) measurement using the two-microphone method is still a young technology but it offers great possibilities in the area of sound-intensity analysis, particularly for sound sources with complex shapes. This report describes the characteristics, performance and technological problems of sound-intensity analyzing equipment by using Ono Sokki's dual-channel FFT analyzer CF-900 as an example.
引用
收藏
页码:70 / 72
相关论文
共 50 条
  • [31] Curing efficacy of a high-light-intensity LED curing unit.
    Yamada, M.
    Miyazaki, M.
    Onose, H.
    Matoba, K.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B131 - B131
  • [32] A simple method of measuring the intensity of sound.
    Pierce, GW
    PROCEEDINGS OF THE AMERICAN ACADEMY OF ARTS AND SCIENCES, 1908, 43 (13/22): : 377 - 395
  • [33] Measuring Amazon Rainfall Intensity With Sound Recorders
    Xavier, R. S.
    Gosset, M.
    Maciel, T. F.
    Bicudo, T.
    Nascimento, L. A. do
    Ramalho, E.
    Fleischmann, A.
    GEOPHYSICAL RESEARCH LETTERS, 2024, 51 (20)
  • [34] EFFECTS OF VARYING DISTRIBUTION OF GENERALIZATION STIMULI WITHIN A CONSTANT RANGE UPON BISECTION OF A SOUND-INTENSITY INTERVAL BY RATS
    RASLEAR, TG
    JOURNAL OF THE EXPERIMENTAL ANALYSIS OF BEHAVIOR, 1975, 23 (03) : 369 - 375
  • [35] USE OF PITCH-AZIMUTH PLOTS IN DETERMINING THE DIRECTION OF A NOISE SOURCE IN WATER WITH A VECTOR SOUND-INTENSITY PROBE
    HICKLING, R
    WEI, W
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (02): : 856 - 866
  • [36] AUXILIARY UNIT FOR A SPECTRUM ANALYZER WHEN MEASURING INTERMODULATION DISTORTION
    FRENKEL, VG
    SHTERENGAS, MS
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (04): : 385 - 387
  • [37] EFFECT OF THE POSITION OF THE BARRIER ON THE INTENSITY OF gamma RADIATION BEHIND THE COLLIMATOR OF THE DETECTION UNIT.
    Zav'yalkin, F.M.
    D'yachenko, V.I.
    Zubkov, Yu.G.
    The Soviet journal of nondestructive testing, 1980, 16 (09): : 637 - 640
  • [38] SOUND INTENSITY AND NOISE EVALUATION IN A CRITICAL CARE UNIT
    Lawson, Nancy
    Thompson, Kim
    Saunders, Gabrielle
    Saiz, Jaya
    Richardson, Jeannette
    Brown, Deborah
    Ince, Naomi
    Caldwell, Marc
    Pope, Diana
    AMERICAN JOURNAL OF CRITICAL CARE, 2010, 19 (06) : E88 - E99
  • [39] A NEW METHOD OF MEASURING SOUND POWER LEVEL USING SOUND INTENSITY MEASUREMENT
    XU, DA
    ZHENG, Y
    ENGINEERING FOR ENVIRONMENTAL NOISE CONTROL, VOLS 1 AND 2: INTER-NOISE 89, 1989, : 1025 - 1028
  • [40] POSSIBILITIES AND LIMITS OF SOUND POWER MEASUREMENTS WITH A REAL-TIME INTENSITY ANALYZER
    STIRNEMANN, A
    BOLLETER, U
    RATHE, EJ
    JOURNAL OF SOUND AND VIBRATION, 1985, 98 (03) : 403 - 413