New technique for radon measurement based on a combination of a track-etch detector and activated charcoal

被引:0
|
作者
Sutej, T. [1 ]
Krizman, M. [1 ]
Ilic, R. [1 ]
机构
[1] Univ of Ljubljana, Ljubljana, Yugoslavia
来源
关键词
CR-39 Detectors - Solid State Nuclear Track Detectors;
D O I
暂无
中图分类号
学科分类号
摘要
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. Here charcoal acts as a radon collector from the air and the track-etch detector as a recorder of alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon utilizing Deodorant activated charcoal (TOK, Yugoslavia) and CR-39 track-etch detector is 1.4 tracks cm-2/Bqm-3 d, which is about eight times higher than that obtained with a standard track-etch dosimeter.
引用
收藏
页码:423 / 424
相关论文
共 50 条
  • [31] Radon determination by activated charcoal adsorption and liquid scintillation measurement
    A. C. Canoba
    F. O. López
    A. A. Oliveira
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 240 : 237 - 241
  • [32] RESPONSE OF A NEW CHARCOAL-ETCHED RADON TRACK DOSIMETER
    SUTEJ, T
    ILIC, R
    KRIZMAN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (03): : 441 - 443
  • [33] Can track-etch detector CR-39 record low-velocity GUT magnetic monopoles?
    He, YD
    PHYSICAL REVIEW D, 1998, 57 (05): : 3182 - 3185
  • [34] FAST AND MULTIFUNCTIONAL METHOD OF RADON MEASUREMENT USING TRACK DETECTOR
    TIAN, ZH
    XIAO, DT
    ZO, FQ
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 475 - 478
  • [35] Environmental risk measurement: Uncertainties for charcoal and alpha-track radon monitors
    Mushrush, GW
    Mose, DG
    Sullivan, KT
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1997, 32 (02): : 427 - 443
  • [36] Environmental risk measurement: Uncertainties for charcoal and alpha-track radon monitors
    Mushrush, George W.
    Mose, Douglas G.
    Sullivan, Karen T.
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 32 (02): : 427 - 443
  • [37] Simulation of the skim-off method in radon measurement by activated charcoal
    Urosevic, V
    Nikezic, D
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (01) : 121 - 124
  • [38] New method of the precise measurement for the thickness and bulk etch rate of the solid-state track detector
    Kodaira, S.
    Yasuda, N.
    Hasebe, N.
    Doke, T.
    Ota, S.
    Ogura, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (01): : 163 - 170
  • [39] FAILED FUEL-ELEMENT DETECTION BY DELAYED NEUTRONS USING SOLID-STATE TRACK-ETCH TECHNIQUE
    BOCK, H
    MULLER, HG
    SULEIMAN, M
    ATOMKERNENERGIE-KERNTECHNIK, 1979, 34 (02): : 105 - 111
  • [40] EXPERIMENTAL-STUDY OF CHARCOAL ADSORPTIVE TECHNIQUE FOR MEASUREMENT OF RADON IN AIR
    SHIMO, M
    IKEBE, Y
    MAEDA, J
    KAMIMURA, R
    HAYASHI, K
    ISHIGURO, A
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1983, 25 (07): : 562 - 570