Environmental risk measurement: Uncertainties for charcoal and alpha-track radon monitors

被引:1
|
作者
Mushrush, GW [1 ]
Mose, DG [1 ]
Sullivan, KT [1 ]
机构
[1] MARYMOUNT UNIV,DEPT HLTH PROMOT MANAGEMENT,ARLINGTON,VA 22207
关键词
radon monitors; radon; alpha-track; risk assessment;
D O I
10.1080/10934529709376552
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ability of activated charcoal and alpha-track radon monitors to estimate annual concentrations is a consequence of the measurement interval over which either type of monitor is used. In a case study of several hundred homes in Virginia and Maryland, a +/- 90% uncertainty must be applied to a single charcoal measurements to estimate the annual radon concentration, and a +/- 50% uncertainty must be applied to a three-month alpha-track measurement (90% confidence levels).
引用
收藏
页码:427 / 443
页数:17
相关论文
共 33 条
  • [1] Environmental risk measurement: Uncertainties for charcoal and alpha-track radon monitors
    Mushrush, George W.
    Mose, Douglas G.
    Sullivan, Karen T.
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 32 (02): : 427 - 443
  • [2] A MULTIYEAR QUALITY-CONTROL STUDY OF ALPHA-TRACK RADON MONITORS
    PEARSON, MD
    MARTZ, DE
    GEORGE, JL
    LANGNER, GH
    HEALTH PHYSICS, 1992, 62 (01): : 87 - 90
  • [3] A PERFORMANCE EVALUATION STUDY OF 3 TYPES OF ALPHA-TRACK DETECTOR RADON MONITORS
    YEAGER, WM
    LUCAS, RM
    DAUM, KA
    SENSINTAFFAR, E
    POPPELL, S
    FELDT, L
    CLARKIN, M
    HEALTH PHYSICS, 1991, 60 (04): : 507 - 515
  • [4] Environmental radon monitoring: comparing drawbacks and performances of charcoal canisters, alpha-track and E-PERM detectors
    Gervino, G
    Bonetti, R
    Cigolini, C
    Marino, C
    Prati, P
    Pruiti, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 452 - 455
  • [5] CALIBRATION OF ALPHA-TRACK MONITORS FOR MEASUREMENT OF THORON (RN-220)
    PEARSON, MD
    SPANGLER, RR
    HEALTH PHYSICS, 1991, 60 (05): : 697 - 701
  • [6] MEASUREMENT OF RADON IN AIR BY ALPHA-TRACK METHOD ENHANCEMENT OF DETECTION SENSITIVITY USING A LAMP
    MAKI, Y
    TANAKA, F
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1983, 79 (01): : 141 - 146
  • [7] MEASUREMENT UNCERTAINTIES OF LONG-TERM RN-222 AVERAGES AT ENVIRONMENTAL LEVELS USING ALPHA-TRACK DETECTORS
    NELSON, RA
    HEALTH PHYSICS, 1987, 53 (05): : 447 - 453
  • [8] HOME-MADE ALPHA-TRACK DETECTOR FOR RADIOACTIVE GAS: RADON
    Cucu, Marina Ionela
    Dupleac, Daniel
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2020, 82 (04): : 287 - 294
  • [9] Instrument performance of a radon measuring system with the alpha-track detection technique
    Tokonami, S
    Zhuo, W
    Ryuo, H
    Yonehara, H
    Yamada, Y
    Shimo, M
    RADIATION PROTECTION DOSIMETRY, 2003, 103 (01) : 69 - 72
  • [10] Home-made alpha-track detector for radioactive gas: Radon
    Cucu, Marina Ionela
    Dupleac, Daniel
    UPB Scientific Bulletin, Series C: Electrical Engineering and Computer Science, 2020, 82 (04): : 287 - 294