Effect of intraluminal thrombus thickness and bulge diameter on the oxygen diffusion m abdominal aortic aneurysm
被引:0
|
作者:
Vorp, D.A.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Department of Mechanical Engineering, University of Pittsburgh, Pittsburgh, PA 15213, United StatesDepartment of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Vorp, D.A.
[1
,2
]
Wang, D.H.J.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United StatesDepartment of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Wang, D.H.J.
[3
]
Webster, M.W.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United StatesDepartment of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Webster, M.W.
[1
]
Federspiel, W.J.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United StatesDepartment of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
Federspiel, W.J.
[1
,3
]
机构:
[1] Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
[2] Department of Mechanical Engineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
[3] Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
The intraluminal thrombus (ILT) commonly found within abdominal aortic aneurysm (AAA) may serve as a barrier to oxygen diffusion from the lumen to the inner layers of the aortic wall. The purpose of this work was to address this hypothesis and to assess the effects of AAA bulge diameter (dAAA) and ILT thickness (δ) on the oxygen flow. A hypothetical, three-dimensional, axisymmetric model of AAA containing ILT was created for computational analysis. Commercial software was utilized to estimate the volume flow of O2 per cell, which resulted in zero oxygen tension at the AAA wall. Solutions were generated by holding one of the two parameters fixed while varying the other. The supply of O2 to the AAA wall increases slightly and linearly with dAAA for a fixed δ. This slight increase is due to the enlarged area through which diffusion of O2 may take place. The supply of O2 was found to decrease quickly with increasing δ for a fixed dAAA due to the increased resistance to O2 transport by the ILT layer. The presence of even a thin, 3 mm ILT layer causes a diminished O2 supply (less than 4×10-10 μmol/min/cell). Normally functioning smooth muscle cells require a supply of 21×10-10 μmol/min/cell. Thus, our analysis serves to support our hypothesis that the presence of ILT alters the normal pattern of O2 supply to the AAA wall. This may lead to hypoxic cell dysfunction in the AAA wall, which may further lead to wall weakening and increased potential for rupture.
机构:
Sichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Qiu, Yue
Wang, Yi
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ Sci & Engn, Dept Comp Sci, Zigong 643000, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Wang, Yi
Fan, Yubo
论文数: 0引用数: 0
h-index: 0
机构:
Beihang Univ, Sch Biol Sci & Med Engn, Minist Educ, Key Lab Biomech & Mechanobiol, Beijing 100191, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Fan, Yubo
Peng, Liqing
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Peng, Liqing
Liu, Rong
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Inst Text & Clothing, Hong Kong, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Liu, Rong
Zhao, Jichun
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Dept Vasc Surg, West China Hosp, Chengdu 610041, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Zhao, Jichun
Yuan, Ding
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Dept Vasc Surg, West China Hosp, Chengdu 610041, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China
Yuan, Ding
Zheng, Tinghui
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R ChinaSichuan Univ, Dept Appl Mech, Chengdu 610065, Sichuan, Peoples R China