Effect of intraluminal thrombus thickness and bulge diameter on the oxygen diffusion m abdominal aortic aneurysm

被引:0
|
作者
Vorp, D.A. [1 ,2 ]
Wang, D.H.J. [3 ]
Webster, M.W. [1 ]
Federspiel, W.J. [1 ,3 ]
机构
[1] Department of Surgery, University of Pittsburgh, Pittsburgh, PA 15213, United States
[2] Department of Mechanical Engineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
[3] Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States
来源
Journal of Biomechanical Engineering | 1998年 / 120卷 / 05期
关键词
Blood vessels - Computer simulation - Diffusion in solids - Oxygen;
D O I
暂无
中图分类号
学科分类号
摘要
The intraluminal thrombus (ILT) commonly found within abdominal aortic aneurysm (AAA) may serve as a barrier to oxygen diffusion from the lumen to the inner layers of the aortic wall. The purpose of this work was to address this hypothesis and to assess the effects of AAA bulge diameter (dAAA) and ILT thickness (δ) on the oxygen flow. A hypothetical, three-dimensional, axisymmetric model of AAA containing ILT was created for computational analysis. Commercial software was utilized to estimate the volume flow of O2 per cell, which resulted in zero oxygen tension at the AAA wall. Solutions were generated by holding one of the two parameters fixed while varying the other. The supply of O2 to the AAA wall increases slightly and linearly with dAAA for a fixed δ. This slight increase is due to the enlarged area through which diffusion of O2 may take place. The supply of O2 was found to decrease quickly with increasing δ for a fixed dAAA due to the increased resistance to O2 transport by the ILT layer. The presence of even a thin, 3 mm ILT layer causes a diminished O2 supply (less than 4×10-10 μmol/min/cell). Normally functioning smooth muscle cells require a supply of 21×10-10 μmol/min/cell. Thus, our analysis serves to support our hypothesis that the presence of ILT alters the normal pattern of O2 supply to the AAA wall. This may lead to hypoxic cell dysfunction in the AAA wall, which may further lead to wall weakening and increased potential for rupture.
引用
收藏
页码:579 / 583
相关论文
共 50 条
  • [21] Effect of variation in intraluminal thrombus constitutive properties on abdominal aortic aneurysm wall stress
    Di Martino, ES
    Vorp, DA
    ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (07) : 804 - 809
  • [22] Effect of Variation in Intraluminal Thrombus Constitutive Properties on Abdominal Aortic Aneurysm Wall Stress
    Elena S. Di Martino
    David A. Vorp
    Annals of Biomedical Engineering, 2003, 31 : 804 - 809
  • [23] Mechanical properties and microstructure of intraluminal thrombus from abdominal aortic aneurysm
    Wang, DHJ
    Makaroun, M
    Webster, MW
    Vorp, DA
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (06): : 536 - 539
  • [24] Does the Intraluminal Thrombus Provoke the Rupture of the Abdominal Aortic Aneurysm Wall?
    Almijalli, Mohammed
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [25] Intraluminal abdominal aortic aneurysm thrombus is associated with disruption of wall integrity
    Koole, Dave
    Zandvoort, Herman J. A.
    Schoneveld, Arjan
    Vink, Aryan
    Vos, Jan A.
    van den Hoogen, Luuk L.
    de Vries, Jean-Paul P. M.
    Pasterkamp, Gerard
    Moll, Frans L.
    van Herwaarden, Joost A.
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 77 - 83
  • [26] On the Relative Impact of Intraluminal Thrombus Heterogeneity on Abdominal Aortic Aneurysm Mechanics
    Leach, Joseph R.
    Kao, Evan
    Zhu, Chengcheng
    Saloner, David
    Hope, Michael D.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (11):
  • [27] Hemodynamic effects of intraluminal thrombus burden in an idealized abdominal aortic aneurysm
    Alp Kalipcilar
    Huseyin Enes Salman
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [28] Hemodynamic effects of intraluminal thrombus burden in an idealized abdominal aortic aneurysm
    Kalipcilar, Alp
    Salman, Huseyin Enes
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (10)
  • [29] Computational analysis of oxygen transport in a patient-specific model of abdominal aortic aneurysm with intraluminal thrombus
    Sun, N.
    Leung, J. H.
    Wood, N. B.
    Hughes, A. D.
    Thom, S. A.
    Cheshire, N. J.
    Xu, X. Y.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 : S18 - S23
  • [30] Effect of intraluminal thrombus on wall stress in patient-specific models of abdominal aortic aneurysm
    Wang, DHJ
    Makaroun, MS
    Webster, MW
    Vorp, DA
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) : 598 - 604