Seismic design guidelines and provisions for steel-framed buildings: FEMA 267/267A and 1997 AISC Seismic Provisions

被引:0
|
作者
Malley, James O.
Carter, Charles J.
Saunders, C. Mark
机构
关键词
D O I
10.1193/1.1586090
中图分类号
学科分类号
摘要
One of the important surprises of the Northridge earthquake of January 17, 1994, was the widespread and unanticipated brittle fracture of welded steel beam-to-column connections. Although no casualties or collapses occurred during the Northridge earthquake as a result of these connection failures, and many WSMF buildings were not damaged at all, a wide spectrum of brittle connection damage did occur, ranging from minor cracking to completely severed columns. This paper summarizes two of the most important documents that have been developed in response to the damage suffered to steel moment frame buildings in the Northridge earthquake. The first, FEMA 267, Interim Guidelines: Evaluation, Repair, Modification and Design of Welded Steel Moment Frame Structures, was generated from studies undertaken as part of a project initiated by the U.S. Federal Emergency Management Agency (FEMA) to reduce the earthquake hazards posed by steel moment-resisting frame buildings. The second document addressed in this paper is the 1997 edition of the American Institute of Steel Construction (AISC) Seismic Provisions for Structural Steel Buildings (commonly referred to as the AISC Seismic Provisions) that incorporates the new information generated by the FEMA-sponsored project and other investigations on the seismic performance of steel structures, and has been adopted by reference into the 2000 International Building Code (IBC).