Amperometric carbohydrate detection in flow systems by means of a bismuth modified platinum electrode

被引:0
|
作者
Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103 Leipzig, Germany [1 ]
机构
来源
Fresenius J Anal Chem | / 3-4卷 / 274-278期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Amperometric carbohydrate detection in flow systems by means of a bismuth modified platinum electrode
    Strubing, A
    Wittstock, G
    Szargan, R
    Werner, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (3-4): : 274 - 278
  • [2] FLOW-INJECTION DETERMINATION OF NITRITE BY AMPEROMETRIC DETECTION AT A MODIFIED ELECTRODE
    COX, JA
    KULKARNI, KR
    ANALYST, 1986, 111 (10) : 1219 - 1220
  • [3] Utilization of a platinum-modified carbon fiber electrode in capillary electrophoresis with amperometric detection
    Zhou, WH
    Xu, L
    Wu, MJ
    Xu, LJ
    Wang, EK
    CHINESE SCIENCE BULLETIN, 1996, 41 (01): : 34 - 37
  • [4] Utilization of a platinum-modified carbon fiber electrode in capillary electrophoresis with amperometric detection
    周伟红
    许亮
    吴明嘉
    许莉娟
    汪尔康
    Chinese Science Bulletin, 1996, (01) : 34 - 37
  • [5] Copper Modified Platinum Electrode for Amperometric Detection of Spectinomycin Sulfate by Anion Exchange Chromatography
    Ren Dan-Dan
    Xi Ling-Ling
    Huang Wei-Min
    Zhu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (11) : 1563 - 1567
  • [6] AMPEROMETRIC DETECTION OF NONELECTROACTIVE CATIONS IN FLOW SYSTEMS AT A CUPRIC HEXACYANOFERRATE ELECTRODE
    THOMSEN, KN
    BALDWIN, RP
    ANALYTICAL CHEMISTRY, 1989, 61 (23) : 2594 - 2598
  • [7] FLOW-INJECTION DETERMINATION OF METHIONINE WITH AMPEROMETRIC DETECTION AT A STABLE MODIFIED ELECTRODE
    COX, JA
    DABEKZLOTORZYNSKA, E
    ELECTROANALYSIS, 1991, 3 (03) : 239 - 242
  • [8] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [9] Platinum particles-modified electrode for HPLC with pulsed amperometric detection of thiols in rat striatum
    Cao, XN
    Li, JH
    Xu, HH
    Lin, L
    Xian, YZ
    Yamamoto, K
    Jin, LT
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (08) : 564 - 569
  • [10] Amperometric biosensors based on deposition of gold and platinum nanoparticles on polyvinylferrocene modified electrode for xanthine detection
    Bas, Salih Zeki
    Gulce, Handan
    Yildiz, Salih
    Gulce, Ahmet
    TALANTA, 2011, 87 : 189 - 196