Amperometric carbohydrate detection in flow systems by means of a bismuth modified platinum electrode

被引:0
|
作者
Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103 Leipzig, Germany [1 ]
机构
来源
Fresenius J Anal Chem | / 3-4卷 / 274-278期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Development of a cellobiose dehydrogenase modified electrode for amperometric detection of diphenols
    Lindgren, A
    Stoica, L
    Ruzgas, T
    Ciucu, A
    Gorton, L
    ANALYST, 1999, 124 (04) : 527 - 532
  • [32] Amperometric Detection of Histamine with a Pyrroloquinoline-Quinone Modified Electrode
    Young, Joshua A.
    Jiang, Xiayu
    Kirchhoff, Jon R.
    ELECTROANALYSIS, 2013, 25 (07) : 1589 - 1593
  • [33] Amperometric detection of methanol with a methanol dehydrogenase modified electrode sensor
    Liu, Qinfeng
    Kirchhoff, Jon R.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 601 (1-2) : 125 - 131
  • [34] A bienzyme modified carbon paste electrode for amperometric detection of pyruvate
    Bergmann, W
    Rudolph, R
    Spohn, U
    ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 233 - 241
  • [35] Flow-Injection Amperometric Determination of Urine Glucose Using Platinum Electrode Modified with Nafion® and Saccharide Substitued Polypyrrole
    Yasuzawa, Mikito
    Kitahara, Makoto
    Yabutani, Tomoki
    Motonaka, Junko
    BUNSEKI KAGAKU, 2009, 58 (11) : 941 - 944
  • [36] Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2017, 29 (06) : 1626 - 1634
  • [37] A Sensitive Amperometric Sensor for the Determination of Dopamine at Graphene and Bismuth Nanocomposite Film Modified Electrode
    Mani, Veerappan
    Devasenathipathy, Rajkumar
    Chen, Shen-Ming
    Kohilarani, Karuppasamy
    Ramachandran, Rasu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1199 - 1207
  • [38] The evolution of amperometric sensing from the bare to the modified electrode systems
    Seeber, Renato
    Terzi, Fabio
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (7-8) : 1523 - 1534
  • [39] The evolution of amperometric sensing from the bare to the modified electrode systems
    Renato Seeber
    Fabio Terzi
    Journal of Solid State Electrochemistry, 2011, 15 : 1523 - 1534
  • [40] Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode
    Castro, SSL
    Balbo, VR
    Barbeira, PJS
    Stradiotto, NR
    TALANTA, 2001, 55 (02) : 249 - 254