Platinum particles-modified electrode for HPLC with pulsed amperometric detection of thiols in rat striatum

被引:24
|
作者
Cao, XN
Li, JH
Xu, HH
Lin, L
Xian, YZ
Yamamoto, K
Jin, LT [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] BAS Co Ltd, Sumida Ku, Tokyo 131, Japan
关键词
pulsed amperometric detection; Pt particles; L-cysteine; glutathione; penicillamine; striatum;
D O I
10.1002/bmc.357
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new chemically modified electrode based on the immobilization of Pt particles is fabricated and exhibits electrocatalytic oxidation for L-cysteine (L-Cys), glutathione (GSH) and penicillamine (PEN) with relatively high sensitivity. It is also adaptable to HPLC for pulsed amperometric detection (PAD) of these thiols. PAD largely improves the detection sensitivity because the alternated polarizations can effectively clean and reactivate the electrode surface. It is shown that the peak currents Of L-CYS, GSH and PEN are linear to their concentrations, with the calculated detection limit of 1.1x10(-7), 1.8x10(-7) and 3.8x10(-7) mol L-1. respectively (S/N=3). The method has been successfully applied to assess the contents Of L-Cys and GSH in rat striatal microdialysates. The average contents of the two analytes in rat striatum are 2.6x10(-6) and 2.8x10(-6) mol L-1, respectively. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:564 / 569
页数:6
相关论文
共 50 条
  • [1] In vivo monitoring of the thiols in rat striatum by liquid chromatography with amperometric detection at a functionalized multi-wall carbon nanotubes modified electrode
    Cao, XN
    Lin, L
    Xian, YZ
    Zhang, W
    Xie, YF
    Jin, LT
    ELECTROANALYSIS, 2003, 15 (10) : 892 - 897
  • [2] AMPEROMETRIC TITRATION OF THIOLS WITH A STATIONARY PLATINUM ELECTRODE
    RICHMOND, DV
    SOMERS, E
    CHEMISTRY & INDUSTRY, 1966, (01) : 18 - &
  • [4] Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode
    Almira Ramanaviciene
    Arunas Ramanavicius
    Analytical and Bioanalytical Chemistry, 2004, 379 : 287 - 293
  • [5] Pulsed amperometric detection of DNA with an ssDNA/polypyrrole-modified electrode
    Ramanaviciene, A
    Ramanavicius, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) : 287 - 293
  • [6] Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode
    Inoue, T
    Kirchhoff, JR
    ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1349 - 1354
  • [7] Amperometric carbohydrate detection in flow systems by means of a bismuth modified platinum electrode
    Strubing, A
    Wittstock, G
    Szargan, R
    Werner, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (3-4): : 274 - 278
  • [8] Amperometric carbohydrate detection in flow systems by means of a bismuth modified platinum electrode
    Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103 Leipzig, Germany
    Fresenius J Anal Chem, 3-4 (274-278):
  • [9] Analysis of phenolic acids in plant materials using HPLC with amperometric detection at a platinum tubular electrode
    Jirovsky, D
    Horáková, D
    Kotoucek, M
    Valentová, K
    Ulrichová, J
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (08): : 739 - 742
  • [10] Utilization of a platinum-modified carbon fiber electrode in capillary electrophoresis with amperometric detection
    Zhou, WH
    Xu, L
    Wu, MJ
    Xu, LJ
    Wang, EK
    CHINESE SCIENCE BULLETIN, 1996, 41 (01): : 34 - 37