Refractometer for tracking changes in the refractive index of air near 780 nm

被引:0
|
作者
Khélifa, N. [1 ]
Fang, H. [1 ]
Xu, J. [1 ,2 ]
Juncar, P. [1 ]
Himbert, M. [1 ,3 ]
机构
[1] Conserv. Natl. des Arts et Metiers, Bureau National de Métrologie, Institut de Métrologie, 292 rue Saint Martin, 75003 Paris, France
[2] National Institute of Metrology, 7 District 11, 100013 Beijing, China
[3] Laboratoire de Physique des Lasers, URA Ctr. Natl. de la Rech. Sci. 282, Université Paris-Nord, 93430 Villetaneuse, France
来源
Applied Optics | 1998年 / 37卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new system, consisting of a double-channel Fabry-Perot etalon and laser diodes emitting around 780 nm, is described and proposed for use for measuring air-refractive index. The principle of this refractometer is based on frequency measurements between optical laser sources. It permits quasi-instantaneous measurement with a resolution of better than 10-9and uncertainty in the 10-8range. Some preliminary results on the stability of this system and the measurements of the refractive index of air with this apparatus are presented. The first measurements of the index of air at 780 nm are, within an experimental uncertainty of the order of 2 × 10-8, in agreement with the predicted values by the so-called revised Edlén equations. This result is, to the best of our knowledge, the first to extend to the near IR the validity of the revised Edlén equation derived for the wavelength range of 350-650 nm. © 1998 Optical Society of America.
引用
收藏
页码:156 / 161
相关论文
共 50 条
  • [41] Absolute air refractive index measurement and tracking based on variable length vacuum cell
    Yu, Xiangzhi
    Zhang, Tieli
    Ellis, Jonathan D.
    OPTICAL ENGINEERING, 2016, 55 (06)
  • [42] A DIFFERENTIAL SURFACE REFRACTOMETER FOR TESTING FOR VARIATION OF REFRACTIVE INDEX IN LARGE PLATES OF GLASS
    WATSON, JT
    JOOS, G
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (11) : 876 - 876
  • [43] Optoelectronic refractometer characterized by high sensitivity over a wide range of refractive index
    Bali, LM
    Srivastava, A
    Shukla, RK
    Srivastava, P
    Kulshreshtha, A
    Srivastava, A
    Kumar, M
    OPTICAL ENGINEERING, 2002, 41 (10) : 2627 - 2635
  • [44] Behavior of 157 nm excimer-laser-induced refractive index changes in silica
    Smith, Charlene M.
    Borrelli, Nicholas F.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2006, 23 (09) : 1815 - 1821
  • [45] Effect of the Absorbance of a Flowing Liquid on the Error of the Refractive Index Measured with a Differential Refractometer
    Davydov, V. V.
    Moroz, A., V
    OPTICS AND SPECTROSCOPY, 2020, 128 (09) : 1415 - 1420
  • [46] Optical refractometer for complex refractive index measurement in UV-NIR range
    Plucinskia, J
    Rätyb, J
    Keränenb, E
    OPTOELECTRONIC AND ELECTRONIC SENSORS III, 1999, 3730 : 118 - 121
  • [47] Measurements of refractive index sensitivity using long-period grating refractometer
    Chong, JH
    Shum, P
    Haryono, H
    Yohana, A
    Rao, MK
    Lu, C
    Zhu, YN
    OPTICS COMMUNICATIONS, 2004, 229 (1-6) : 65 - 69
  • [48] Effect of the Absorbance of a Flowing Liquid on the Error of the Refractive Index Measured with a Differential Refractometer
    V. V. Davydov
    A. V. Moroz
    Optics and Spectroscopy, 2020, 128 : 1415 - 1420
  • [49] Metamaterial infrared refractometer for detecting broadband complex refractive index of liquid material
    Kagami, Hibiki
    Amemiya, Tomohiro
    Masuda, Keisuke
    Tanaka, Makoto
    Nishiyama, Nobuhiko
    Arai, Shigehisa
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [50] Laser interference refractometer for monitoring the absolute index of refraction of air
    Yu. V. Mishchenko
    Measurement Techniques, 1998, 41 : 334 - 342