Effect of the Absorbance of a Flowing Liquid on the Error of the Refractive Index Measured with a Differential Refractometer

被引:5
|
作者
Davydov, V. V. [1 ]
Moroz, A., V [1 ]
机构
[1] St Petersburg Polytech Univ, St Petersburg 195251, Russia
关键词
refractive index; flowing liquid; differential refractometer; measurement error; SYSTEM;
D O I
10.1134/S0030400X20090076
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We determined the factors that affect the measurement error of the refractive indexnin a flowing liquid (a change in its absorbance and temperature). When a flow-through differential refractometer is used to measure the refractive index of a flowing liquid, the error in measuring is additionally affected by the scattering of radiation in the cell converter and the wedge shape of the cell glasses. A new differential refractometer is developed designed for studying the effect of the absorbance of a flowing liquid on the measurement error of the refractive index. New results are obtained confirming this effect, and a new procedure for compensating it is proposed.
引用
收藏
页码:1415 / 1420
页数:6
相关论文
共 50 条
  • [1] Effect of the Absorbance of a Flowing Liquid on the Error of the Refractive Index Measured with a Differential Refractometer
    V. V. Davydov
    A. V. Moroz
    Optics and Spectroscopy, 2020, 128 : 1415 - 1420
  • [2] Liquid refractive index measured through a refractometer based on diffraction gratings
    Calixto, Sergio
    Piazza, Valeria
    Gonzalez-Suarez, Alan M.
    Garcia-Cordero, Jose L.
    Bruce, Neil C.
    Rosete-Aguilar, Martha
    Garnica, Guillermo
    OPTICS EXPRESS, 2019, 27 (24) : 34705 - 34720
  • [3] The effect of optical density of the flowing liquid on the measurement error of its refractive index
    Grebenikova, N. M.
    Davydov, V. V.
    INTERNATIONAL CONFERENCE PHYSICA.SPB/2019, 2019, 1400
  • [4] EFFECT OF THE WEDGE ANGLE OF THE PRISM IN THE CELL DIFFERENTIAL REFRACTOMETER ON THE ERROR IN MEASURING THE REFRACTIVE-INDEX
    KARABEGOV, MA
    KOMRAKOV, YI
    KHURSHUDYAN, SA
    INDUSTRIAL LABORATORY, 1979, 45 (04): : 444 - 447
  • [5] Phase error evaluation technique based on Fourier transform for refractive index detection limit of microfluidic differential refractometer
    Ji, Weibang
    Zhang, Jianguo
    OPTIK, 2016, 127 (19): : 7973 - 7977
  • [6] New Method for Measuring the Refractive Index of Flowing Liquid
    V. V. Davydov
    A. V. Moroz
    D. I. Nikolaev
    Optics and Spectroscopy, 2021, 129 : 915 - 921
  • [7] New Method for Measuring the Refractive Index of Flowing Liquid
    Davydov, V. V.
    Moroz, A. V.
    Nikolaev, D. I.
    OPTICS AND SPECTROSCOPY, 2021, 129 (08) : 915 - 921
  • [8] A DIFFERENTIAL SURFACE REFRACTOMETER FOR TESTING FOR VARIATION OF REFRACTIVE INDEX IN LARGE PLATES OF GLASS
    WATSON, JT
    JOOS, G
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (11) : 876 - 876
  • [9] Metamaterial infrared refractometer for detecting broadband complex refractive index of liquid material
    Kagami, Hibiki
    Amemiya, Tomohiro
    Masuda, Keisuke
    Tanaka, Makoto
    Nishiyama, Nobuhiko
    Arai, Shigehisa
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [10] EFFECT OF THE OPTICAL-DENSITY OF LIQUIDS ON THE ERROR OF A DIFFERENTIAL REFRACTOMETER
    KARABEGOV, MA
    KOMRAKOV, YI
    KHURSHUDYAN, SA
    MEASUREMENT TECHNIQUES, 1981, 24 (03) : 248 - 250