DETECTION UNIT WITH CORRELATION CHARGE-SENSITIVE PREAMPLIFIER.

被引:0
|
作者
Pod'yachev, V.N.
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A semiconductor detection unit for x radiation is described, with a correlated charge-sensitive preamplifier that enables the signal-to-noise ratio to be increased by a factor of ROOT 2 compared to the normal scheme. A method of measuring detector and resistor noise with the aid of the preamplifier is also described. An energy resolution of 196 ev for the K// alpha Fe line can be achieved with a detector having a sensitive region 5 mm in diameter by 2. 5 mm deep, with an energy equivalent of 167 ev.
引用
收藏
页码:944 / 947
相关论文
共 50 条
  • [41] Charge-sensitive preamplifier with continuous reset by means of the gate-to-drain current of the JFET integrated on the detector
    Fiorini, C
    Lechner, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1147 - 1151
  • [42] FAST CHARGE-SENSITIVE PREAMPLIFIER FOR SOFT-X-RAY ASTRONOMY APPLICATIONS OF MULTIWIRE PROPORTIONAL CHAMBERS
    AURIEMMA, G
    GIOVANNE.F
    MENGUCCI, C
    NUCLEAR INSTRUMENTS & METHODS, 1973, 113 (03): : 473 - 475
  • [43] Simulation of High-Temperature Performance and Electronic Noise of SiC-JFET for Charge-Sensitive Preamplifier
    Zhang, Rui
    Chen, Size
    Han, Yuncheng
    Li, Taosheng
    Guo, Haomin
    Wang, Ying
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (11) : 2490 - 2498
  • [44] A wide bandwidth, high linearity hybrid charge-sensitive preamplifier for high-capacitance silicon detectors
    Bassini, R
    Boiano, C
    Pagano, A
    Pullia, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1224 - 1227
  • [45] GATED CHARGE SENSITIVE PREAMPLIFIER
    EAST, LV
    NUCLEAR INSTRUMENTS & METHODS, 1969, 71 (03): : 328 - &
  • [46] Evaluation of the Spectroscopic Performance of the Integrated Multi-Channel Charge-Sensitive Preamplifier of TRACE with a Silicon Detector Prototype
    Capra, Stefano
    Aliaga, Ramon J.
    Mengoni, Daniele
    John, Philipp R.
    Gadea, Andres
    Herrero, Vicente
    Pullia, Alberto
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [47] CHARGE-SENSITIVE AMPLIFIER - SOME GENERALIZATION
    KRASNOKUTSKY, RN
    FEDYAKIN, NN
    SHUVALOV, RS
    RADIOTEKHNIKA I ELEKTRONIKA, 1989, 34 (11): : 2376 - 2387
  • [48] Experimental performance of a highly-innovative low-noise charge-sensitive preamplifier with integrated range-booster
    Pullia, A.
    Capra, S.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [49] A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
    Paulus, MJ
    Rochelle, JM
    Andreaco, MS
    Binkley, DM
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 330 - 334
  • [50] Integrated front-end electronics in a detector compatible process: source-follower and charge-sensitive preamplifier configurations
    Ratti, L
    Manghisoni, M
    Re, V
    Speziali, V
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 : 141 - 151