DETECTION UNIT WITH CORRELATION CHARGE-SENSITIVE PREAMPLIFIER.

被引:0
|
作者
Pod'yachev, V.N.
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A semiconductor detection unit for x radiation is described, with a correlated charge-sensitive preamplifier that enables the signal-to-noise ratio to be increased by a factor of ROOT 2 compared to the normal scheme. A method of measuring detector and resistor noise with the aid of the preamplifier is also described. An energy resolution of 196 ev for the K// alpha Fe line can be achieved with a detector having a sensitive region 5 mm in diameter by 2. 5 mm deep, with an energy equivalent of 167 ev.
引用
收藏
页码:944 / 947
相关论文
共 50 条
  • [21] A ultra fast hybrid charge-sensitive preamplifier for high-capacitance detectors
    Boiano, C.
    Bassini, R.
    Pagano, A.
    Pullia, A.
    Riboldi, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 338 - +
  • [22] A versatile high-speed bipolar charge-sensitive preamplifier for calorimeter applications
    Baschirotto, A
    Castello, R
    Pessina, G
    Rancoita, PG
    Seidman, A
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (04) : 635 - 639
  • [23] PERFORMANCE EVALUATION OF AN INNOVATIVE INTEGRATED CHARGE-SENSITIVE PREAMPLIFIER WITH DYNAMIC RANGE BOOSTER
    Pullia, A.
    Capra, S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [24] CHARGE-SENSITIVE PREAMPLIFIER WITH DRAIN FEEDBACK FOR X-RAY SPECTROMETER.
    Sinitsyn, V.N.
    Ginzburg, Yu.N.
    Instruments and experimental techniques New York, 1986, 29 (5 pt 2): : 1120 - 1122
  • [25] A low-noise current-sensitive preamplifier for X-ray computed tomography with applying a charge-sensitive preamplifier
    Kanno, Ikuo
    Onabe, Hideaki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2021, 58 (01) : 100 - 106
  • [26] Application of Charge-Sensitive Preamplifier for the Calibration of Partial Discharge Calibrators Below 1 pC
    Havunen, Jussi
    Hallstrom, Jari
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (06) : 2034 - 2040
  • [27] Application of Charge-Sensitive Preamplifier for the Calibration of Partial Discharge Calibrators below 1 pC
    Havunen, Jussi
    Hallstrom, Jari
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [28] A Low-Power CMOS 0.13 μm Charge-Sensitive Preamplifier for GEM Detectors
    Pezzotta, A.
    Costantini, A.
    De Matteis, M.
    D'Amico, S.
    Gorini, G.
    Murtas, F.
    Baschirotto, A.
    2013 INTERNATIONAL CONFERENCE ON IC DESIGN AND TECHNOLOGY (ICICDT), 2013, : 147 - 150
  • [29] DEVELOPMENT AND EVALUATION OF CHARGE-SENSITIVE PREAMPLIFIER FOR CSI CALORIMETER IN THE KEK B-FACTORY
    TANAKA, M
    IKEDA, H
    TAMAI, K
    TAKEMOTO, M
    HAYASHII, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1208 - 1211
  • [30] CHARGE-SENSITIVE RECORDER
    ANTONEVICH, AI
    BUTSKII, VV
    VETOKHIN, SS
    SARZHEVSKII, AM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (06) : 1680 - 1680