Effect of overhead ground wires on reduction of failure rates of surge arresters on power distribution lines

被引:0
|
作者
Nakada, K. [1 ]
Yokota, T. [1 ]
Yokoyama, Sh. [1 ]
Asakawa, A. [1 ]
Kawabata, T. [1 ]
机构
[1] Central Research Inst of the, Electric Power Industry
关键词
Applications; (APP);
D O I
10.1002/(SICI)1520-6416(19980130)122:23.0.CO;2-Z
中图分类号
学科分类号
摘要
Surge arresters are sometimes damaged by lightning strokes with high energy, in spite of installation of conventional protection methods. In order to reduce the number of failures of surge arresters, we should consider another protection method, such as an increase in the withstand capability of surge arresters and installation of additional overhead ground wires. However, quantitative comparison of these methods for preventing damage to surge arresters against lightning strokes with high energy has never been performed. This paper describes the effects of additional overhead ground wires for preventing damage to surge arresters. The main results are: (1) The failure rate of surge arresters on a distribution line with two overhead ground wires is about one third of that with an overhead ground wire. (2) Installation of a second overhead ground wire six to eight spans from the end of a line reduces the failure rate of a surge arrester at the end as effectively as increasing the withstand capability by a factor of two.
引用
收藏
页码:12 / 20
相关论文
共 50 条
  • [41] Analysis of technical possibilities of reduction of the corona effect based on digital simulations of the electric field intensity by phase wires of overhead power lines
    Sztafrowski, Dariusz
    Gumiela, Jacek
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (01): : 113 - 116
  • [42] Effect of solar radiation on power losses and capacity of insulated and non-insulated wires of overhead power LINES
    Girshin, Stanilav S.
    Sorokin, Igor A.
    Smerdin, Aleksandr N.
    Bigun, Aleksandr A. Y.
    Petrova, Elena, V
    Trotsenko, Vladislav M.
    Goryunov, Vladimir N.
    Smorodin, George S.
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (06): : 59 - 63
  • [43] Methodology for Design of Magnetorheological Dampers to Protect Wires of Overhead Power Lines
    Ermolaev, A.I.
    Erofeev, V.I.
    Tishin, I.V.
    Russian Engineering Research, 2024, 44 (07) : 895 - 903
  • [44] On the Refinement of Calculations of Load Losses of Electricity in the Wires of Overhead Power Lines
    Shvedov G.V.
    Shchepotin A.S.
    Shvedov, G.V. (journal-elektrotechnika@mail.ru), 1600, Pleiades journals (91): : 398 - 402
  • [45] Features of Temperature Monitoring of Overhead Power Transmission Lines with Insulated Wires
    Vikharev A.P.
    Power Technology and Engineering, 2019, 53 (03) : 383 - 385
  • [46] Practical Schemes on Lightning Energy Suppression in Arresters for Transformers on 10 kV Overhead Distribution Lines
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Qi, Ruihan
    Li, Binghao
    Chen, Mingli
    Li, Zhe
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 4272 - 4281
  • [47] Mitigation of lightning-induced overvoltages in medium voltage distribution lines by means of periodical grounding of shielding wires and of surge arresters: Modeling and experimental validation
    Paolone, M
    Nucci, CA
    Petrache, E
    Rachidi, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) : 423 - 431
  • [48] Development of surge arresters with series gap against lightning breakage of covered conductors on distribution lines
    Gu, Shanqiang
    Chen, Weijiang
    He, Jinliang
    Shen, Haibin
    Zhang, Shan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2191 - 2198
  • [49] Improvement of Overhead Transmission Lines Lightning Protection by Line Arresters with Separate Groundings and Shielding Wires Fixed at Insulation Racks
    Podporkin, G., V
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1180 - 1191
  • [50] Effect of the grounding resistance to the behaviour of high-voltage transmission lines' surge arresters
    Christodoulou, Christos A.
    Ekonomou, Lambros
    Papanikolaou, Nikolaos
    Gonos, Ioannis F.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2014, 8 (06) : 470 - 478