Improvement of Overhead Transmission Lines Lightning Protection by Line Arresters with Separate Groundings and Shielding Wires Fixed at Insulation Racks

被引:0
|
作者
Podporkin, G., V [1 ]
机构
[1] Streamer, 27 Gzhatskaya, St Petersburg, Russia
关键词
Overhead lines; Lightning protection; Grounding;
D O I
10.1007/978-3-030-31676-1_110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper sets out a proposal aimed at increasing efficiency of overhead lines lightning protection by using lightning arresters only on one phase (e.g. A) and stand-alone grounding. If it is not metal-connected to the pole it is connected to the pole via earth. Due to the current flow in the earth around the grounding there is distribution of potential, which decreases with offset from the grounding. Conducting pole located at a distance from the grounding gets a potential. Thus, voltage applied to phase B insulator decreases and the probability of its flashover is reduced. However, there is a possibility of phase A insulator flashover. By application grounding at optimal distance from the pole lightning protection level can be twice greater than at traditional pole grounding with the same value of grounding resistance. Efficiency of application of insulating racks for fixing shielding wires connected to standing alone groundings is also shown. Use of standing alone groundings for connection of lightning arresters on the power lines, as well as use of insulation racks for shielding wire with grounding, located at an optimal distance from the poles, appear to be effective technical solutions deserving further elaboration with participation of scientific, design and operational organizations.
引用
收藏
页码:1180 / 1191
页数:12
相关论文
共 11 条
  • [1] Lightning protection of the overhead transmission lines long spans without ground wires by using line arresters
    Savic, Milan
    Banjanin, Mladen
    2024 23RD INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA, INFOTEH, 2024,
  • [2] Improvement of the lightning shielding performance of overhead transmission lines by passive shield wires
    Metwally, IA
    Heidler, FH
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) : 378 - 392
  • [3] Lightning protection of overhead transmission lines using external ground wires
    Banjanin, Mladen S.
    Savic, Milan S.
    Stojkovic, Zlatan M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 127 : 206 - 212
  • [4] Line arresters and underbuilt wire application in lightning protection of 110 kV and 220 kV overhead transmission lines
    Banjanin, Mladen
    2019 18TH INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2019,
  • [5] Design and application of line surge arresters to improve lightning protection characteristics of transmission lines
    He, Jin-Liang
    Zeng, Rong
    Hu, Jun
    Chen, Shui-Ming
    Zhao, Jie
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1562 - +
  • [6] Simulation of Line Surge Arresters for Lightning Protection in 10kV Transmission Lines
    Wang Yong
    Xie Pu
    Zhao Jin-cheng
    Zhang Gui-fang
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 269 - +
  • [7] Simulation research on improvement of lightning shielding level of long spans of EHV overhead lines by installing surge arresters
    Tian, Hong
    Wang, Ning
    Chen, Tianxiang
    Zhang, Ji
    Wu, Yan
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (01): : 63 - 68
  • [8] Lightning attachment models and maximum shielding failure current of overhead transmission lines: implications in insulation coordination of substations
    Mikropoulos, P. N.
    Tsovilis, T. E.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (12) : 1299 - 1313
  • [9] Lightning Shielding Protection Design and Actualization of 1000-kV UHVAC Overhead Transmission Line in China
    Yuan, Jun
    Yu, Zhanqing
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1578 - 1581
  • [10] Use of line surge arresters for the improvement of the lightning performance of 63 kV and 90 kV shielded and unshielded transmission lines
    Sadovic, S
    Joulie, R
    Tartier, S
    Brocard, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (03) : 1232 - 1240