ATTENUATION OF THE NEUTRON DOSE EQUIVALENT IN A LABYRINTH THROUGH AN ACCELERATOR SHIELD.

被引:0
|
作者
TESCH, K.
机构
来源
| 1982年 / V 12卷 / N 3期
关键词
ACCELERATORS; -; ACCESSORIES;
D O I
暂无
中图分类号
学科分类号
摘要
THE ATTENUATION OF NEUTRON DOSE EQUIVALENT IN CONCRETE LABYRINTHS WITH RECTANGULAR BENDS WAS STUDIED BY MEANS OF NEUTRON SOURCES AND REM COUNTERS. THE NUMBER OF BENDS, THE LENGTH OF EACH SECTION, AND THE WIDTH OF THE LABYRINTH COULD BE VARIED. THE RESULTS OF THESE MEASUREMENTS WERE COMPARED WITH THE DOSE EQUIVALENT ATTENUATION FOUND IN A LABYRINTH AT THE DESY 7-GEV ELECTRON SYNCHROTRON, WITH PUBLISHED DATA FROM A PROTON ACCELERATOR AND FROM A NUCLEAR REACTOR. AN EMPIRICAL FORMULA DESCRIBING THE NEUTRON DOSE EQUIVALENT IS PRESENTED.
引用
收藏
页码:169 / 175
相关论文
共 50 条
  • [41] NEUTRON DOSE EQUIVALENT OUTSIDE THE LATERAL SHIELDING OF AN ELECTRON LINEAR-ACCELERATOR OPERATING AT 0.48-2.15 GEV
    HIRAYAMA, H
    BAN, S
    HEALTH PHYSICS, 1989, 56 (06): : 947 - 952
  • [42] STATE PRIMARY STANDARDS OF EQUIVALENT DOSE AND EQUIVALENT DOSE-RATE UNITS OF NEUTRON RADIATION
    YANOVSKII, AP
    YUDIN, MF
    POPRUZHKO, LA
    FROLOV, VV
    LYSAK, YD
    MEASUREMENT TECHNIQUES, 1976, 19 (03) : 404 - 408
  • [43] TISSUE-EQUIVALENT PROPORTIONAL COUNTERS IN NEUTRON SHIELD EFFECTIVENESS STUDIES
    BRACKENB.LW
    ENDRES, GWR
    FAUST, LG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01): : 418 - &
  • [44] CALCULATIONS OF EFFECTIVE DOSE EQUIVALENT, AMBIENT DOSE EQUIVALENT AND INDIVIDUAL DOSE EQUIVALENT FOR A SET OF REFERENCE NEUTRON-SPECTRA AND FIELD GEOMETRIES
    BARTLETT, DT
    GREENHALGH, JR
    HEALTH PHYSICS, 1986, 50 (04): : 548 - 550
  • [45] Experimental neutron attenuation measurements in possible fast reactor shield materials
    Nyarku, Mawutorli
    Keshavamurthy, Ramanathapura S.
    Subramanian, Venkata D.
    Haridas, Adish
    Glover, Eric T.
    ANNALS OF NUCLEAR ENERGY, 2013, 53 : 135 - 139
  • [46] The Research on Neutron Dose Equivalent Meter for Pulse Neutron Radiation Field
    Wang, Weizhen
    Kang, Kejun
    Li, Jianmin
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1614 - 1620
  • [48] Evaluation of equivalent dose to eye lens through dose equivalent Hp(3)
    Marcantonini, Marta
    Chiappiniello, Andrea
    Beneventi, Sara
    Reggioli, Valentina
    Dipilato, Anna C.
    Fulcheri, Christian P. L.
    Iacco, Martina
    Zucchetti, Claudio
    Tarducci, Roberto
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 29 - 32
  • [49] The evaluation of neutron and gamma ray dose equivalent distributions in patients and the effectiveness of shield materials for high energy photons radiotherapy facilities
    Ghassoun, J.
    Senhou, N.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (04) : 620 - 624
  • [50] DETERMINATION OF ABSORBED DOSE, DOSE EQUIVALENT, AND BIOLOGICAL NEUTRON DOSE FROM NEUTRON FLUENCE WITH SPECIAL REGARD TO SPECTRAL CHANGES IN NEUTRON FIELD AFTER TRANSMISSION THROUGH IRON, WATER AND CONCRETE SHIELDS
    DORSCHEL, B
    HERFORTH, L
    KERNENERGIE, 1977, 20 (05): : 136 - 141