ATTENUATION OF THE NEUTRON DOSE EQUIVALENT IN A LABYRINTH THROUGH AN ACCELERATOR SHIELD.

被引:0
|
作者
TESCH, K.
机构
来源
| 1982年 / V 12卷 / N 3期
关键词
ACCELERATORS; -; ACCESSORIES;
D O I
暂无
中图分类号
学科分类号
摘要
THE ATTENUATION OF NEUTRON DOSE EQUIVALENT IN CONCRETE LABYRINTHS WITH RECTANGULAR BENDS WAS STUDIED BY MEANS OF NEUTRON SOURCES AND REM COUNTERS. THE NUMBER OF BENDS, THE LENGTH OF EACH SECTION, AND THE WIDTH OF THE LABYRINTH COULD BE VARIED. THE RESULTS OF THESE MEASUREMENTS WERE COMPARED WITH THE DOSE EQUIVALENT ATTENUATION FOUND IN A LABYRINTH AT THE DESY 7-GEV ELECTRON SYNCHROTRON, WITH PUBLISHED DATA FROM A PROTON ACCELERATOR AND FROM A NUCLEAR REACTOR. AN EMPIRICAL FORMULA DESCRIBING THE NEUTRON DOSE EQUIVALENT IS PRESENTED.
引用
收藏
页码:169 / 175
相关论文
共 50 条
  • [21] HIGH-ENERGY ACCELERATOR SHIELD -LEAKAGE NEUTRON SPECTRA
    OBRIEN, K
    SANNA, R
    ALBERG, M
    MCLAUGHLIN, JE
    ROTHENBERG, SA
    NUCLEAR SCIENCE AND ENGINEERING, 1967, 27 (02) : 338 - +
  • [22] HIGH-ENERGY ACCELERATOR SHIELD LEAKAGE NEUTRON SPECTRA
    OBRIEN, K
    SANNA, R
    ALBERG, M
    MCLAUGHL.JE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1966, 9 (02): : 354 - +
  • [23] A SPHERICAL DOSE EQUIVALENT NEUTRON DETECTOR
    LEAKE, JW
    NUCLEAR INSTRUMENTS & METHODS, 1966, 45 (01): : 151 - &
  • [24] An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy
    Zhang, Rui
    Perez-Andujar, Angelica
    Fontenot, Jonas D.
    Taddei, Phillip J.
    Newhauser, Wayne D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 6975 - 6985
  • [25] Neutron dose equivalent at depth in a phantom
    Kry, S.
    Followill, D.
    Salehpour, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2474 - 2474
  • [26] A PORTABLE NEUTRON DOSE EQUIVALENT METER
    ROGERS, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (05) : 8 - &
  • [27] ACCELERATOR NEUTRON SPECTRA AND SPECTRA TO DOSE CONVERSION
    GILBERT, WS
    PATTERSO.HW
    SMITH, AR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (01): : 392 - &
  • [28] Fluence and dose measurements for an accelerator neutron beam
    Liu, Z.
    Lyun, S. H.
    McNeill, F. E.
    Mothersill, C. E.
    Seymour, C. B.
    Prestwich, W. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 326 - 328
  • [29] The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator
    Ivkovic, Ana
    Faj, Dario
    Kasabasic, Mladen
    Sovilj, Marina Poje
    paKrn, Ivana
    Branilovic, Marina Grabar
    Brkic, Hrvoje
    RADIOLOGY AND ONCOLOGY, 2020, 54 (02) : 247 - 252
  • [30] USE OF PERSONNEL NEUTRON FILM MONITORING TO DETERMINE EQUIVALENT RADIATION-DOSE BEHIND PROTON ACCELERATOR SHIELDING
    GELFAND, EK
    KOMOCHKOV, MM
    MANKO, BV
    SALATSKAYA, MM
    SYCHEV, BS
    SOVIET ATOMIC ENERGY, 1980, 49 (02): : 550 - 555