Rapid analysis for plutonium-239 in urine by magnetic sector inductively coupled plasma-mass spectrometry using Aridus desolvation introduction system

被引:0
|
作者
机构
[1] Ting, Bill G.
[2] Pappas, R. Steve
[3] Paschal, Dan C.
来源
Ting, B.G. (BTing@CDC.GOV) | 1600年 / Royal Society of Chemistry卷 / 18期
关键词
Inductively coupled plasma - Isotopes - Mass spectrometry - Metal analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Inductively coupled plasma-mass spectrometry (ICP-MS) is a useful method for assessing environmental or occupational exposure to thorium, uranium, plutonium, and other actinides. In this study, we investigated method parameters for practical balance between sample preparation time, volume, and sufficient sensitivity (limit of detection 47 fg per 10 mL urine) for reasonable exposure assessment of the maximum number of samples in the minimum possible turnaround time for unintentional exposures or emergency response situations using magnetic sector desolvation-ICP-MS. The method accuracy for urinary 239Pu determination was within 2% of target at 100 pg L-1 (p > 0.9995) and 7.7 pg L-1 (p > 0.9995), whereas our data was 16% disparate to target at approximately 45 pg L-1 (p -1 (p > 0.0005) concentrations for data obtained from the determination of 239Pu in internally prepared urine pools and in pools characterized by an external agency. Precisions based on relative standard deviations ranged from 8% at 100 pg L-1 to 39% at 7.6 pg L-1 239Pu.
引用
收藏
相关论文
共 50 条
  • [41] Evaluation of a modified ion lens system for inductively coupled plasma-mass spectrometry
    BonchinCleland, SL
    Cleland, TJ
    Olson, LK
    Caruso, JA
    AMERICAN LABORATORY, 1996, 28 (03) : P34 - &
  • [42] Stripping analysis combined on-line with inductively coupled plasma-atomic emission spectrometry and with inductively coupled plasma-mass spectrometry
    Zhou, FM
    ELECTROANALYSIS, 1996, 8 (10) : 855 - 861
  • [43] Screening of elemental impurities in commercial detonation nanodiamond using sector field inductively coupled plasma-mass spectrometry
    Dimitar P. Mitev
    Ashley T. Townsend
    Brett Paull
    Pavel N. Nesterenko
    Journal of Materials Science, 2014, 49 : 3573 - 3591
  • [44] Trace metal analysis using inductively coupled plasma-mass spectrometry (ICP-MS).
    Lee, S
    Oh, H
    Choi, Y
    Kim, J
    Kim, S
    CLINICAL CHEMISTRY, 2004, 50 (06) : A58 - A58
  • [45] Screening of elemental impurities in commercial detonation nanodiamond using sector field inductively coupled plasma-mass spectrometry
    Mitev, Dimitar P.
    Townsend, Ashley T.
    Paull, Brett
    Nesterenko, Pavel N.
    JOURNAL OF MATERIALS SCIENCE, 2014, 49 (10) : 3573 - 3591
  • [47] Uranium colloid analysis by single particle inductively coupled plasma-mass spectrometry
    Degueldre, C
    Favarger, PY
    Rossé, R
    Wold, S
    TALANTA, 2006, 68 (03) : 623 - 628
  • [48] Zirconia colloid analysis by single particle inductively coupled plasma-mass spectrometry
    Degueldre, C
    Favarger, PY
    Bitea, C
    ANALYTICA CHIMICA ACTA, 2004, 518 (1-2) : 137 - 142
  • [49] Application of laser ablation inductively coupled plasma-mass spectrometry in dendrochemical analysis
    Watmough, SA
    Hutchinson, TC
    Evans, RD
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (01) : 114 - 118
  • [50] Lead Fractionation Analysis in Lipstick Samples by Inductively Coupled Plasma-Mass Spectrometry
    Yilmazcan, Ozlem
    Erdemir, Umran Seven
    Izgi, Belgin
    Ozer, Elif Tumay
    Gucer, Seref