Rapid analysis for plutonium-239 in urine by magnetic sector inductively coupled plasma-mass spectrometry using Aridus desolvation introduction system

被引:0
|
作者
机构
[1] Ting, Bill G.
[2] Pappas, R. Steve
[3] Paschal, Dan C.
来源
Ting, B.G. (BTing@CDC.GOV) | 1600年 / Royal Society of Chemistry卷 / 18期
关键词
Inductively coupled plasma - Isotopes - Mass spectrometry - Metal analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Inductively coupled plasma-mass spectrometry (ICP-MS) is a useful method for assessing environmental or occupational exposure to thorium, uranium, plutonium, and other actinides. In this study, we investigated method parameters for practical balance between sample preparation time, volume, and sufficient sensitivity (limit of detection 47 fg per 10 mL urine) for reasonable exposure assessment of the maximum number of samples in the minimum possible turnaround time for unintentional exposures or emergency response situations using magnetic sector desolvation-ICP-MS. The method accuracy for urinary 239Pu determination was within 2% of target at 100 pg L-1 (p > 0.9995) and 7.7 pg L-1 (p > 0.9995), whereas our data was 16% disparate to target at approximately 45 pg L-1 (p -1 (p > 0.0005) concentrations for data obtained from the determination of 239Pu in internally prepared urine pools and in pools characterized by an external agency. Precisions based on relative standard deviations ranged from 8% at 100 pg L-1 to 39% at 7.6 pg L-1 239Pu.
引用
收藏
相关论文
共 50 条
  • [31] Semiquantitative analysis of biological materials by inductively coupled plasma-mass spectrometry
    Amarasiriwardena, D
    Durrant, SF
    Lasztity, A
    Krushevska, A
    Argentine, MD
    Barnes, RM
    MICROCHEMICAL JOURNAL, 1997, 56 (03) : 352 - 372
  • [32] RAPID DETERMINATION OF 237NP AND PLUTONIUM ISOTOPES IN URINE BY INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY
    Maxwell, Sherrod L.
    Culligan, Brian K.
    Jones, Vernon D.
    Nichols, Sheldon T.
    Noyes, Gary W.
    Bernard, Maureen A.
    HEALTH PHYSICS, 2011, 101 (02): : 180 - 186
  • [33] Analysis of iodine in food samples by inductively coupled plasma-mass spectrometry
    Todorov, Todor I.
    Gray, Patrick J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2016, 33 (02): : 282 - 290
  • [34] Multielemental analysis of human fetal tissues using inductively coupled plasma-mass spectrometry
    Yves Gélinas
    Julie Lafond
    Jean-Pierre Schmit
    Biological Trace Element Research, 1997, 59 : 63 - 74
  • [35] Chemical analysis of iron meteorites by inductively coupled plasma-mass spectrometry
    D'Orazio, M
    Folco, L
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2003, 27 (03): : 215 - 225
  • [36] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF METALS ON MEMBRANE FILTERS
    NORTHINGTON, DJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (12): : 977 - 979
  • [37] Semiquantitative Analysis of Biological Materials by Inductively Coupled Plasma-Mass Spectrometry
    Amarasiriwardena, D.
    Durrant, S. F.
    Laszitty, A.
    Krushevska, A.
    Microchemical Journal, 56 (03):
  • [38] ON THE TRAIL OF ARSENIC IN THE ENVIRONMENT USING COUPLED CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    EBDON, L
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 29 - ANYL
  • [39] SIMULTANEOUS DETERMINATION OF LEAD, BISMUTH AND THALLIUM IN PLASMA AND URINE BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    MAURAS, Y
    PREMELCABIC, A
    BERRE, S
    ALLAIN, P
    CLINICA CHIMICA ACTA, 1993, 218 (02) : 201 - 205
  • [40] Comparison of a high temperature torch integrated sample introduction system with a desolvation system for the analysis of microsamples through inductively coupled plasma mass spectrometry
    Sanchez, Raquel
    Canabate, Agueda
    Bresson, Carole
    Chartier, Frederic
    Isnard, Helene
    Maestre, Salvador
    Nonell, Anthony
    Todoli, Jose-Luis
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 129 : 28 - 36