Response functions for electrons from 1 to 12 Mev have been measured with a plastic scintillator telescope. A parameterization model for these response functions has been found to give good results at all energies. Furthermore it was established that the type of reflector used for the scintillator has a considerable influence on the response functions. A mechanism for this influence has been proposed and tested by Monte Carlo calculations.
引用
收藏
页码:379 / 385
相关论文
共 50 条
  • [31] Radioactive Noble Gas Detection and Measurement with Plastic Scintillators
    Mitev, Krasimir
    Cassette, Philippe
    PLASTIC SCINTILLATORS: CHEMISTRY AND APPLICATIONS, 2021, 140 : 385 - 423
  • [32] Neutron Detection with Large Plastic Scintillators for RPM Applications
    Corre, G.
    Boudergui, K.
    Sannie, G.
    Kondrasovs, V.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [34] Thoron (220Rn) detection with plastic scintillators
    Mitev, Krasimir K.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [35] Study of non-linear energy response of POLAR plastic scintillators to electrons
    Zhang, Xiaofeng
    Xiao, Hualin
    Yu, Boxiang
    Orsi, Silvio
    Wu, Bobing
    Hu, Wei
    Zhang, Xuan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 797 : 94 - 100
  • [36] THEORETICAL AND EXPERIMENTAL DEPTH-DOSE CURVES FOR ELECTRONS IN ENERGY RANGE 3-10 MEV
    LILLICRAP, SC
    ROSENBLOOM, M
    BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (531): : 229 - +
  • [37] DETECTION EFFICIENCY OF PLASTIC SCINTILLATION COUNTERS FOR NEUTRONS IN ENERGY RANGE 20-130 MEV
    CRABB, DG
    MCEWEN, JG
    AULD, EG
    LANGSFOR.A
    NUCLEAR INSTRUMENTS & METHODS, 1967, 48 (01): : 87 - &
  • [38] The response of lead-tungstate scintillators (PWO) to photons with energies in the range 13 MeV-64 MeV
    von Wurtemberg, K. Marcks
    Geren, L.
    Lundberg, O.
    Tegner, P-E.
    Fransson, K.
    Grape, S.
    Johansson, T.
    Thome, E.
    Wolke, M.
    Brudvik, J.
    Fissum, K.
    Hansen, K.
    Isaksson, L.
    Lundin, M.
    Schroder, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 679 : 36 - 43
  • [39] New applications of 10 MeV electrons for reeled goods
    Günthard, C
    Lee, DW
    RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (3-6) : 641 - 645
  • [40] THE NUCLEAR SCATTERING OF ELECTRONS AND POSITRONS AT 10-MEV
    BOSLEY, W
    HUGHES, IS
    PHILOSOPHICAL MAGAZINE, 1955, 46 (383): : 1281 - 1286