DETECTION OF ELECTRONS IN THE 10 Mev RANGE BY PLASTIC SCINTILLATORS.

被引:0
|
作者
Beaudoin, G. [1 ]
Champagne, A. [1 ]
Jeremie, H. [1 ]
Lessard, L. [1 ]
机构
[1] Univ de Montreal, Montreal, Que, Can, Univ de Montreal, Montreal, Que, Can
来源
关键词
SCINTILLATION COUNTERS;
D O I
暂无
中图分类号
学科分类号
摘要
Response functions for electrons from 1 to 12 Mev have been measured with a plastic scintillator telescope. A parameterization model for these response functions has been found to give good results at all energies. Furthermore it was established that the type of reflector used for the scintillator has a considerable influence on the response functions. A mechanism for this influence has been proposed and tested by Monte Carlo calculations.
引用
收藏
页码:379 / 385
相关论文
共 50 条
  • [21] DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR FOR 10-70 MEV NEUTRONS
    BRADY, FP
    JUNGERMAN, JA
    YOUNG, JC
    ROMERO, JL
    SYMONDS, PJ
    NUCLEAR INSTRUMENTS & METHODS, 1968, 58 (01): : 57 - +
  • [22] DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR FOR NEUTRONS IN THE ENERGY RANGE OF 1 TO 14 MEV
    GRASSLER, H
    TESCH, K
    NUCLEAR INSTRUMENTS & METHODS, 1961, 10 (04): : 353 - 355
  • [23] Fluorescent 1,8-naphthalimides-containing polymers as plastic scintillators. An attempt for neutron-gamma discrimination
    Hamel, Matthieu
    Simic, Vesna
    Normand, Stephane
    REACTIVE & FUNCTIONAL POLYMERS, 2008, 68 (12): : 1671 - 1681
  • [24] Plastic scintillators modifications for a selective radiation detection
    Hamel, Matthieu
    Bertrand, Guillaume H. V.
    Carrel, Frederick
    Coulon, Romain
    Dumazert, Jonathan
    Montbarbon, Eva
    Sguerra, Fabien
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [25] Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility
    Giguere, Cloe
    Hart, Alexander
    Bateman, Joseph
    Korysko, Pierre
    Farabolini, Wilfrid
    Lechasseur, Yoan
    Bazalova-Carter, Magdalena
    Beaulieu, Luc
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (07):
  • [26] DETECTION EFFICIENCY OF PLASTIC-SCINTILLATION COUNTERS (NE 110) FOR NEUTRONS IN THE ENERGY-RANGE OF 10-40 MEV
    ABDELWAHAB, MS
    BIALY, J
    SCHMIDT, FK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 200 (2-3): : 291 - 293
  • [27] THE DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR FOR NEUTRONS IN THE ENERGY RANGE OF 21-29 MEV
    GATTI, G
    HILLMAN, P
    MIDDELKOOP, WC
    YAMAGATA, T
    ZAVATTINI, E
    NUCLEAR INSTRUMENTS & METHODS, 1964, 29 (01): : 77 - 82
  • [28] INDUCTION AND DETECTION OF RADIOACTIVITY IN FOODSTUFFS IRRADIATED WITH 10 MEV ELECTRONS AND X-RAYS
    WAKEFORD, CA
    BLACKBURN, R
    SWALLOW, AJ
    RADIATION PHYSICS AND CHEMISTRY, 1991, 38 (01): : 29 - 38
  • [29] DESIGN AND PERFORMANCE OF AN ARRAY OF PLASTIC SCINTILLATORS FOR DETECTING NEUTRONS OF 1.0 TO 450 MEV
    ELFIELD, M
    STANTON, NR
    EDWARDS, KW
    ABOLINS, MA
    REAY, NW
    LIN, MT
    MILLER, EL
    NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (02): : 237 - &
  • [30] RESPONSE OF NAI ANTHRACENE AND PLASTIC SCINTILLATORS TO ELECTRONS AND PROBLEMS OF DETECTING LOW ENERGY ELECTRONS WITH SCINTILLATION COUNTERS
    PORTER, FT
    FREEDMAN, MS
    WAGNER, F
    SHERMAN, IS
    NUCLEAR INSTRUMENTS & METHODS, 1966, 39 (01): : 35 - &