On the possibility of degradation of a control valve of 200 MW unit during start up

被引:0
|
作者
Radulski, W. [1 ]
Bielecki, M. [1 ]
Karcz, M. [1 ]
Badur, J. [1 ]
机构
[1] Alstom Power Elblag, ul. Stoczniowa 2, 82-300 Elblag, Poland
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Elements and structures in power plants, especially in combined cycle or supercritical power plants are frequently subjected to serve high thermal and mechanical stresses in the condition of the stress corrosion damage. Repeated loading due to start up and shout down or normal operation cycles may lead to corrosion-fatigue failure. Complex states of deformation are common within those elements since different sources of cycling loading may differ in phase and frequency. In the case of high operating temperatures, the irreversible creep deformation may add to the complexity of problem. In the article this problem has been analyzed using 3D Computational Fluid Dynamics (CFD) and 3D Computational Structural Mechanics (FEM).
引用
收藏
页码:221 / 230
相关论文
共 50 条
  • [31] Pressure pulsation during low head start-up transient in a pumped-storage hydropower unit
    Chen H.
    Liu H.
    Wang Y.
    Zhou D.
    Xu H.
    Kan K.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (06): : 63 - 72
  • [32] Research on the Dynamic Cavitation Flow Characteristics in the Control Valve Region During the Opening Process of the Valve in an Electronic Unit Pump
    Liang, Yuxiu
    Liu, Fushui
    Li, Yikai
    An, Xiaodong
    IEEE ACCESS, 2020, 8 : 128200 - 128212
  • [33] Mitigating PEMFC Degradation During Start-Up: Locally Resolved Experimental Analysis and Transient Physical Modelling
    Colombo, Elena
    Bisello, Andrea
    Casalegno, Andrea
    Baricci, Andrea
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [34] Control of Passing the Resonance Zone During Start-up of Above Resonance Vibration Machines
    Nozhenko, Viktoriia
    Rodkin, Dmytro
    Bohatyrov, Kostyantin
    PROCEEDINGS OF THE 2019 IEEE INTERNATIONAL CONFERENCE ON MODERN ELECTRICAL AND ENERGY SYSTEMS (MEES'2019), 2019, : 146 - 149
  • [35] Fault Degradation State Prediction under Closed-loop Control for 1000MW Ultra Supercritical Unit
    Weng, Bingya
    Zhao, Chunhui
    Fan, Haidong
    Zheng, Weijian
    Sun, Youxian
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 1337 - 1342
  • [36] Dynamic Characteristics of the Steam Generator of the 200 MW Unit of the Beloyarskaya Nuclear Power Plant as an Object of Control of Temperature of Superheated Steam.
    Komarov, A.N.
    Artemov, A.S.
    Linev, V.I.
    Bronnikov, V.K.
    Gorbunov, A.I.
    Teploenergetika, 1973, (02): : 5 - 9
  • [37] A Case Study of Open- and Closed-Loop Control of Hydrostatic Transmission with Proportional Valve Start-Up Process
    Bury, Pawel
    Stosiak, Michal
    Urbanowicz, Kamil
    Kodura, Apoloniusz
    Kubrak, Michal
    Malesinska, Agnieszka
    ENERGIES, 2022, 15 (05)
  • [38] Conditions of Transfer of Medium Shedding from a Built-in Separator into a Deaerator During Start-up of a 300 MW Monoblock.
    Golyshev, L.V.
    Misyuk, A.V.
    Prokopenko, A.G.
    Lyashenko, L.I.
    Teploenergetika, 1976, (02): : 9 - 12
  • [39] Closed-Loop Precharge Control of Modular Multilevel Converters During Start-Up Processes
    Li, Binbin
    Xu, Dandan
    Zhang, Yi
    Yang, Rongfeng
    Wang, Gaolin
    Wang, Wei
    Xu, Dianguo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) : 524 - 531
  • [40] Cooperative effects of control parameters on the dynamic responses of vehicle powertrain during start-up process
    Wang, Dongyang
    Hu, Minghui
    Qin, Datong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2022, 236 (13) : 2932 - 2948