Dynamic Characteristics of the Steam Generator of the 200 MW Unit of the Beloyarskaya Nuclear Power Plant as an Object of Control of Temperature of Superheated Steam.

被引:0
|
作者
Komarov, A.N.
Artemov, A.S.
Linev, V.I.
Bronnikov, V.K.
Gorbunov, A.I.
机构
来源
Teploenergetika | 1973年 / 02期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Experimental dynamic characteristics of the main parameters of the steam generator of the No. 2 unit of the Beloyarskaya nuclear power plant are presented. A comparative analysis is given of the dynamic characteristics following different disturbances. The possibility of automatic maintenance of the temperature of superheated steam by means of the planned control system is considered.
引用
收藏
页码:5 / 9
相关论文
共 50 条
  • [1] DYNAMIC CHARACTERISTICS OF STEAM-GENERATOR OF A 200 MW UNIT AT BELOYARSK NUCLEAR-POWER STATION CONSIDERED AS AN ELEMENT IN WHICH SUPERHEATED STEAM TEMPERATURE IS CONTROLLED
    KOMAROV, AN
    ARTEMOV, AS
    LINEV, VI
    BRONNIKOV, VK
    GORBUNOV, AI
    THERMAL ENGINEERING, 1973, 20 (02) : 6 - 11
  • [2] A research on superheated steam temperature control optimization of the thermal power plant on the basis of steam temperature characteristics
    Yao Jiafei
    Wang Liyang
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 232 - 238
  • [3] Level control in the steam generator of a nuclear power plant
    Kothare, MV
    Mettler, B
    Morari, M
    Bendotti, P
    Falinower, CM
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2000, 8 (01) : 55 - 69
  • [4] Level control in the steam generator of a nuclear power plant
    Kothare, MV
    Mettler, B
    Morari, M
    Bendotti, P
    Falinower, CM
    PROCEEDINGS OF THE 35TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-4, 1996, : 4851 - 4856
  • [5] Dynamic Characteristics of the Intermediate Superheater of the TPP-200 Steam Generator of the 800 MW Power Unit of the Slavyansk Power Plant Burning Anthracite Fines.
    Berezinets, P.A.
    Berezinets, A.A.
    Kirillov, G.F.
    Bukshtein, I.I.
    Rozengauz, I.N.
    Gotsotsura, B.N.
    1600,
  • [6] Automatic feed control of steam generator in the power unit of a nuclear power plant: Modeling and optimization
    Denisova, L. A.
    AUTOMATION AND REMOTE CONTROL, 2016, 77 (06) : 1084 - 1092
  • [7] Automatic feed control of steam generator in the power unit of a nuclear power plant: Modeling and optimization
    L. A. Denisova
    Automation and Remote Control, 2016, 77 : 1084 - 1092
  • [8] Dynamic Characteristics Analysis of Steam Generator Tube of Nuclear Power Plant by Finite Elements
    Jiang, Shuang
    Cai, Jun
    Zhang, J. W.
    Sun, Q. Z.
    Guo, Xin
    Wang, Y. D.
    APPLIED DECISIONS IN AREA OF MECHANICAL ENGINEERING AND INDUSTRIAL MANUFACTURING, 2014, 577 : 149 - +
  • [9] DYNAMIC RESPONSES OF STEAM TEMPERATURE CONTROL SECTIONS IN TPP-200 BOILER OF 800 MW UNIT
    LISANSKII, ID
    PUGACHEV, LA
    SVIRSKII, SM
    THERMAL ENGINEERING, 1970, 17 (06) : 10 - +
  • [10] Prediction-based feedforward control of superheated steam temperature of a power plant
    Kim, Huiyong
    Kim, Eun Kyo
    Kim, Junghwan
    Lee, Kwang Soon
    Kim, Sungho
    Han, Yeonsu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 71 : 351 - 357