Evaluation of thermal comfort and contamination control for a cleanroom

被引:2
|
作者
Department of Refrigeration and Air-Conditioning, National Chin-Yi University of Technology, Taichung, Taiwan [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
机构
来源
J. Appl. Sci. | 2008年 / 9卷 / 1684-1691期
关键词
Clean rooms - Hosiery manufacture - Laboratories - Thermal comfort;
D O I
10.3923/jas.2008.1684.1691
中图分类号
学科分类号
摘要
There has been a substantial increase in the working environment of cleanroom. Special garments are therefore dressed in all cleanrooms to control particles and microbiological contamination dispersed from personnel in cleanrooms. However, more tightly-woven fabrics of cleanroom garments will result in thermal comfort dissatisfaction. In this study, field tests of a cleanroom have been carried out in our newly constructed MEMS laboratory. The ASHRAE thermal comfort code was conducted to investigate thermal comfort of personnel based on field-testing data consequently. Furthermore, the effects of clothing on thermal comfort and contamination control have been assessed comprehensively. The results from computer simulation and field tests indicated that there existed optimum compromise between the predicted mean vote and airborne particle counts under different cleanroom garments. The contamination control could be achieved by proper types of garments with satisfied thermal comfort of predict mean vote between 0.5-1.0. © 2008 Asian Network for Scientific Information.
引用
收藏
相关论文
共 50 条
  • [41] Evaluation of the thermal comfort condition of an innovative building
    Principi, P
    Di Perna, C
    Ruffini, E
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1911 - 1918
  • [42] Human thermal comfort model and evaluation on building thermal environment
    Wang, Zhaojun
    Yang, Yuxin
    Liu, Chang
    Zhou, Fanzhuo
    Hao, Heyu
    ENERGY AND BUILDINGS, 2024, 323
  • [43] OBJECTIVE AND SUBJECTIVE THERMAL COMFORT EVALUATION IN HUNGARY
    Kajtar, Laszlo
    Nyers, Jozsef
    Szabo, Janos
    Ketskemety, Laszlo
    Herczeg, Levente
    Leitner, Anita
    Bokor, Balazs
    THERMAL SCIENCE, 2017, 21 (03): : 1409 - 1418
  • [44] Contamination impact of Station Brush Fire on cleanroom facilities
    Carey, Phil
    Blakkolb, Brian
    OPTICAL SYSTEM CONTAMINATION: EFFECTS, MEASUREMENTS, AND CONTROL 2010, 2010, 7794
  • [45] TRENDS IN CLEANROOM SELECTION: ALTERNATIVES FOR CONTAMINATION PROTECTION.
    Burnett, James
    Microcontamination, 1986, 4 (05):
  • [46] About Evaluation of Thermal Comfort of Fiber Products
    Tamura, Teruko
    SEN-I GAKKAISHI, 2020, 76 (05) : 175 - 175
  • [47] Thermal comfort evaluation with virtual manikin methods
    Nilsson, Hakan O.
    BUILDING AND ENVIRONMENT, 2007, 42 (12) : 4000 - 4005
  • [48] Thermal comfort evaluation with virtual manikin methods
    Nilsson, HO
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 138 - 142
  • [49] Thermal comfort comparison and evaluation in different climates
    da Silveira Hirashima, Simone Queiroz
    Katzschner, Antje
    Ferreira, Daniele Gomes
    de Assis, Eleonora Sad
    Katzschner, Lutz
    URBAN CLIMATE, 2018, 23 : 219 - 230
  • [50] EVALUATION METHOD OF THERMAL COMFORT IN EXCAVATOR CABIN
    Hwang, Ju Ho
    Lee, Jae Seok
    Kim, Young Hyun
    Kim, Pan Young
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 8A, 2014,