Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

被引:0
|
作者
Okoro N.O.E. [1 ]
Changizi V. [2 ]
Ghareh Bagh E.J. [2 ]
Pak F. [2 ]
机构
[1] Department of Radiology and Radiotherapy Technology, International Campus, Tehran University of Medical Sciences, Tehran
[2] Department of Radiology and Radiotherapy Technology, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran
关键词
Computed Tomography; Image Quality; Optimization; Radiation Dose;
D O I
10.22038/ijmp.2019.40477.1565.
中图分类号
学科分类号
摘要
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(methyl methacrylate) phantom was used for quality control test on CT scanners. Data of 214 scan parameters, dose indicators; volume CT dose index (CTDIvol) and dose-length product (DLP) of patients who underwent cranial CT scans were collected. The data were grouped into three, with respect to the slice numbers of 24, 28, and 32. Tube voltage (kVp) and slice thickness were constant; (110 kVp and 4.8 mm, respectively), at variable tube currents (mAs). A one-sample t-test was used to compare the dose indicator values of the hospital protocol with a recommended protocol. Scan parameters were optimized for radiation dose against image quality. Results: Increased mAs resulted in increased CTDIvol and DLP at constant kVp and slice thickness. Moreover, dose indicators recorded the lowest and highest values at the slice numbers of 24 and 32, respectively. An increase in slice numbers affected dose indicators. Dose indicators recorded significant reduction (P<0.001) in comparison to the recommended protocol. Conclusion: Optimization of CT protocol considers radiation dose and image quality. Radiologists adopted protocols acquired with lower scan parameters and dose indicators lower than the recommended achievable dose limit of 58 mGy. © xxxx **
引用
收藏
页码:322 / 330
页数:8
相关论文
共 50 条
  • [31] Radiation dose in cardiovascular computed tomography
    Gingold, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2345 - 2345
  • [32] Radiation dose in computed tomography of the heart
    Morin, RL
    Gerber, TC
    McCollough, CH
    CIRCULATION, 2003, 107 (06) : 917 - 922
  • [33] Usefulness of Ag Additional Filter on Image Quality and Radiation Dose for Low-Dose Chest Computed Tomography
    Kawamoto, Keishin
    Sato, Hideyuki
    Kogure, Yosuke
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 236 - 243
  • [34] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1814 - 1822
  • [35] Radiation dose and image quality with abdominal computed tomography with automated dose-optimized tube voltage selection
    Hu, Lirong
    Wang, Yujun
    Hou, Hongtao
    Wei, Fuquan
    Yang, Guangzhao
    Chen, Yougeng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (04) : 1011 - 1017
  • [36] Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study
    Yoon, Sungjin
    Yoo, Kwai Han
    Park, So Hyun
    Kim, Hawk
    Lee, Jae Hoon
    Park, Jinny
    Park, Seong Ho
    Kim, Hwa Jung
    PLOS ONE, 2022, 17 (08):
  • [37] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Joana Santos
    Shane Foley
    Graciano Paulo
    Mark F. McEntee
    Louise Rainford
    Pediatric Radiology, 2015, 45 : 1814 - 1822
  • [38] Low dose computed tomography protocol optimization and its influence in radiation dose to the patient
    de Sousa, V.
    Cardoso, G.
    Bento, B.
    Carmona, S.
    Santos, A. I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S80 - S81
  • [39] Image quality and dose in computed tomography
    Jurik, AG
    Jessen, KA
    Hansen, J
    EUROPEAN RADIOLOGY, 1997, 7 (01) : 77 - 81
  • [40] Image quality and dose in computed tomography
    A. G. Jurik
    K. A. Jessen
    J. Hansen
    European Radiology, 1997, 7 : 77 - 81