Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

被引:0
|
作者
Okoro N.O.E. [1 ]
Changizi V. [2 ]
Ghareh Bagh E.J. [2 ]
Pak F. [2 ]
机构
[1] Department of Radiology and Radiotherapy Technology, International Campus, Tehran University of Medical Sciences, Tehran
[2] Department of Radiology and Radiotherapy Technology, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran
关键词
Computed Tomography; Image Quality; Optimization; Radiation Dose;
D O I
10.22038/ijmp.2019.40477.1565.
中图分类号
学科分类号
摘要
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(methyl methacrylate) phantom was used for quality control test on CT scanners. Data of 214 scan parameters, dose indicators; volume CT dose index (CTDIvol) and dose-length product (DLP) of patients who underwent cranial CT scans were collected. The data were grouped into three, with respect to the slice numbers of 24, 28, and 32. Tube voltage (kVp) and slice thickness were constant; (110 kVp and 4.8 mm, respectively), at variable tube currents (mAs). A one-sample t-test was used to compare the dose indicator values of the hospital protocol with a recommended protocol. Scan parameters were optimized for radiation dose against image quality. Results: Increased mAs resulted in increased CTDIvol and DLP at constant kVp and slice thickness. Moreover, dose indicators recorded the lowest and highest values at the slice numbers of 24 and 32, respectively. An increase in slice numbers affected dose indicators. Dose indicators recorded significant reduction (P<0.001) in comparison to the recommended protocol. Conclusion: Optimization of CT protocol considers radiation dose and image quality. Radiologists adopted protocols acquired with lower scan parameters and dose indicators lower than the recommended achievable dose limit of 58 mGy. © xxxx **
引用
收藏
页码:322 / 330
页数:8
相关论文
共 50 条
  • [21] Radiation dose and image quality in spiral computed tomography:: multicentre evaluation at six institutions
    Scheck, RJ
    Coppenrath, EM
    Kellner, MW
    Lehmann, KJ
    Rock, C
    Rieger, J
    Rothmeier, L
    Schweden, F
    Bäuml, AA
    Hahn, K
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 734 - 744
  • [22] Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia
    Saeed, M. K.
    Alzoubi, A. S.
    Al-Qahtani, J. M.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (02) : 279 - 283
  • [23] Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia
    M. K. Saeed
    A. S. Alzoubi
    J. M. Al-Qahtani
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 279 - 283
  • [24] Evaluation of Radiation Dose and Image Quality for TheVarian Cone Beam Computed Tomography System
    Cheng, H.
    Wu, V.
    Liu, E.
    Kwong, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [25] Image quality vs radiation dose of four cone beam computed tomography scanners
    Loubele, M.
    Jacobs, R.
    Maes, F.
    Denis, K.
    White, S.
    Coudyzer, W.
    Lambrichts, I.
    van Steenberghe, D.
    Suetens, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (06) : 309 - 318
  • [26] EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM
    Cheng, Harry C. Y.
    Wu, Vincent W. C.
    Liu, Eva S. F.
    Kwong, Dora L. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 291 - 300
  • [27] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [28] Strategies of computed tomography radiation dose reduction: justification and optimization
    Do, Kyung-Hyun
    Sung, Dong-Wook
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2015, 58 (06): : 534 - 541
  • [29] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [30] FETAL RADIATION DOSE IN COMPUTED TOMOGRAPHY
    Kelaranta, Anna
    Kaasalainen, Touko
    Seuri, Raija
    Toroi, Paula
    Kortesniemi, Mika
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 226 - 230