Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
|
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [41] Patient-specific radiation dose for Chinese pediatric patients undergoing whole-body PET/CT examinations
    Jia, Haoran
    Xue, Mengjia
    Li, Xianru
    Zhuang, Mingzan
    Xie, Tianwu
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [42] International variation in radiation dose for computed tomography examinations: prospective cohort study
    Smith-Bindman, Rebecca
    Wang, Yifei
    Chu, Philip
    Chung, Robert
    Einstein, Andrew J.
    Balcombe, Jonathan
    Cocker, Mary
    Das, Marcos
    Delman, Bradley N.
    Flynn, Michael
    Gould, Robert
    Lee, Ryan K.
    Yellen-Nelson, Thomas
    Schindera, Sebastian
    Seibert, Anthony
    Starkey, Jay
    Suntharalingam, Saravanabavaan
    Wetter, Axel
    Wildberger, Joachim E.
    Miglioretti, Diana L.
    BMJ-BRITISH MEDICAL JOURNAL, 2019, 364
  • [43] Deriving Patient-Specific Radiation Dose Prescription Map Using ADC for Dose Painting of Pancreatic Cancer
    Chen, X.
    Prior, P. W., Jr.
    Tai, A.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E697 - E698
  • [44] Patient-Specific Dosimetry for Pediatric X-Ray Computed Tomography
    Clark, J.
    Stabin, M.
    Pickens, D.
    Price, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [45] Patient-Specific Dosimetry for Pediatric X-Ray Computed Tomography
    Clark, J.
    Pickens, D.
    Stabin, M.
    Price, R.
    MEDICAL PHYSICS, 2010, 37 (06) : 3114 - +
  • [47] Dose and Noise in Abdominal Computed Tomography Examinations
    Staniszewska, Maria A.
    Obrzut, Marzanna
    Cabaj, Anna
    POLISH JOURNAL OF RADIOLOGY, 2007, 72 (04) : 57 - 63
  • [48] Influence of patient-specific anatomy on medical computed tomography and risk evaluation of minimally invasive surgery at the otobasis
    Schieferbein, Vanessa
    Bredemann, Judith
    Schmitt, R.
    Stenin, I.
    Klenzner, T.
    Schipper, Joerg
    Kristin, Julia
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (02) : 375 - 382
  • [49] Influence of patient-specific anatomy on medical computed tomography and risk evaluation of minimally invasive surgery at the otobasis
    Vanessa Schieferbein
    Judith Bredemann
    R. Schmitt
    I. Stenin
    T. Klenzner
    Jörg Schipper
    Julia Kristin
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 375 - 382
  • [50] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158