Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria

被引:0
|
作者
Olaniyan T.A. [1 ]
Aborisade C.A. [1 ]
Balogun F.A. [2 ]
Ogunsina S.A. [1 ]
Saidu A. [3 ]
Ibrahim M.B. [1 ]
机构
[1] Department of Physics, Faculty of Sciences, Obafemi Awolowo University, Ile-Ife
[2] Centre for Energy Research and Development, Obafemi Awolowo University, Ile-Ife
[3] Department of Physics, Faculty of Sciences, Usmanu Danfodiyo University, Sokoto
关键词
BEIR VII model; Computed tomography (CT); Eeffective dose; Radiation protection; Risk assessment;
D O I
10.22038/ijmp.2018.23516.1234
中图分类号
学科分类号
摘要
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT examinations in Ondo, Nigeria. Material and Methods: The study was conducted on 160 patients undergoing eight most common types of CT examinations performed at the center, from December 5, 2015 to February 28, 2016. Body mass index (BMI) was calculated for each patient using demographic data, PSD was determined and estimation of the lifetime attributable risk (LAR) of cancer was accomplished using the Biologic Effects of Ionizing Radiation VII (2006) report phase 2 models. Results: From the results, radiation doses varied significantly within and between the types of CT examinations. The mean ED was 5.88±3.75 mSv in a range of 0.78-19.00 mSv. The mean PSD was 0.274±0.229 mSv/kgm -2 in a range of 0.024-1.555 mSv/kgm -2 and the mean LAR of cancer incidence was 0.04861±0.03996 Sv -1 in a range of 0.00004-0.21942 Sv -1 . Conclusion: ED and PSD varied within and across the CT examinations. In this regard, the coefficients of variation of ED for abdominal, cranial, craniocervical, abdomen/pelvis, thoracic, thoracoabdominal, cervical spine, and pelvis were 5.7%, 6.6%, 3.9%, 8.9%, 3.7%, 6.0%, 44.7%, and 19.2%, respectively. Accordingly, the coefficients of variation of PSD were 9.0%, 7.9%, 7.0%, 10.1%, 5.6%, 23.8%, 47.7%, and 14.2%. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:85 / 90
页数:5
相关论文
共 50 条
  • [21] The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations
    Caro Franck
    Charlot Vandevoorde
    Ingeborg Goethals
    Peter Smeets
    Eric Achten
    Koenraad Verstraete
    Hubert Thierens
    Klaus Bacher
    European Radiology, 2016, 26 : 2646 - 2655
  • [22] A NOVEL METHOD FOR ESTIMATING PATIENT-SPECIFIC PRIMARY DOSE IN CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 71 - 84
  • [23] Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    MEDICAL PHYSICS, 2011, 38 (01) : 408 - 419
  • [24] Patient-Specific Radiation Dose and Cancer Risk Estimation in Pediatric Chest CT: A Study in 30 Patients
    Lia, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [25] Patient effective dose and radiation biological risk in the chest and abdominopelvic computed tomography
    Jamshidi, Mohammad Hossein
    Karami, Aida
    Salimi, Yazdan
    Keshavarz, Amirhesam
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [26] Radiation risk for patients undergoing cardiac computed tomography examinations
    Alkhorayef, M.
    Sulieman, A.
    Alzahrani, Khalid
    Abuzaid, Mohamed
    Alomair, Othman, I
    Almuwannis, M.
    Alghamdi, Salem
    Tamam, Nissren
    Bradley, David A.
    APPLIED RADIATION AND ISOTOPES, 2021, 168
  • [27] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [28] Analysis of Radiation Dose to Pediatric Patients During Computed Tomography Examinations
    Kharbanda, Anupam B.
    Krause, Ernest
    Lu, Yi
    Blumberg, Karen
    ACADEMIC EMERGENCY MEDICINE, 2015, 22 (06) : 670 - 675
  • [29] Changing Radiation Dose From Diagnostic Computed Tomography Examinations in Saskatchewan
    Dumaine, Chance S.
    Leswick, David A.
    Fladeland, Derek A.
    Lim, Hyun J.
    Toews, Lori J.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2012, 63 (03): : 183 - 191
  • [30] Radiation dose of chaperones during common pediatric computed tomography examinations
    Overhoff, Daniel
    Weis, Meike
    Riffel, Philipp
    Sudarski, Sonja
    Froelich, Matthias F.
    Fries, Peter
    Schoenberg, Stefan
    Gawlitza, Joshua
    PEDIATRIC RADIOLOGY, 2020, 50 (08) : 1078 - 1082