Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode

被引:0
|
作者
Nguyen, Do Mai [1 ]
Toan Tran, Thanh Tam [2 ]
Doan, Manh Dung [3 ]
Le, Van Thuan [4 ,5 ]
Dinh, Quang Khieu [1 ]
机构
[1] University of Sciences, Hue University, 530000, Viet Nam
[2] Institute of Applied Technology, Thu Dau Mot University, Binh Duong Province, 75000, Viet Nam
[3] Institute of Biotechnology and Environment, Tay Nguyen University, Buon Ma Thuot,630000, Viet Nam
[4] Center for Advanced Chemistry, Institute of Research and Development, Duy Tan University, 03 Quang Trung, Da Nang,55000, Viet Nam
[5] The Faculty of Natural Sciences, Duy Tan University, 03 Quang Trung, Da Nang,55000, Viet Nam
关键词
Carbon - Electrochemical sensors - Gas adsorption - Glass membrane electrodes - Scanning electron microscopy - Tungsten compounds;
D O I
暂无
中图分类号
学科分类号
摘要
In the present article, the disulfide tungsten/activated carbon derived from Eichhornia crassipes (WS2/AC) was synthesized by the hydrothermal process. The received materials were examined by X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray – mapping, and nitrogen adsorption/desorption isotherms. The morphology of WS2/AC was tailored to have a micro/meso/macro structure that facilized large electric conductivity and quick ion diffusion. The WS2/AC sample was used as an electrode modifier for developing an electrochemical sensor for salbutamol detection. WS2/AC exhibited excellent oxidation toward salbutamol. Through some optimized conditions, the electrochemical signal of the proposed sensor varied linearly to the salbutamol concentration ranging from 1 to 210 μM with a low LOD (detection limit) of 0.52 μM. The developed sensor showed several merits: easy producing, convenient usage, fabulous selectivity, and good repeatability as well as reproducibility. Finally, the suggested technique can be applied to determine salbutamol in people's biological fluid with satisfactory recoveries of 98.5–104.4% and without statistics different from standard HPLC. © 2022 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [31] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251
  • [32] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):
  • [33] Electrochemical Determination of Imidacloprid Using an Electrosynthesized Hexa-Peri-Hexabenzocoronene Modified Glassy Carbon Electrode (GCE) by Differential Pulse Voltammetry (DPV)
    Wang, Rong
    Lin, Tingting
    Nie, Qiyang
    Qin, Caihong
    Luo, Yougang
    Wang, Ruijuan
    Wang, Shulong
    Jing, Yiqi
    ANALYTICAL LETTERS, 2024, 57 (18) : 3103 - 3114
  • [34] Simultaneous Determination of Benserazide and Levodopa in Pharmaceutical Tablet, Human Serum and Urine Sample by Differential Pulse Voltammetry Using Modified Glassy Carbon Electrode
    Naushad, Mu.
    Gupta, V. K.
    Wabaidur, S. M.
    Alothman, Z. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (01): : 297 - 311
  • [35] Poly(catechol) film modified glassy carbon electrode for ultratrace determination of cerium(III) by differential pulse anodic stripping voltammetry
    Khoo, SB
    Zhu, J
    ELECTROANALYSIS, 1999, 11 (08) : 546 - 552
  • [36] Determination of Cadmium(II) by Differential Pulse Voltammetry (DPV) Using a Cerium(IV) Oxide: Polyaniline Composite Modified Glassy Carbon Electrode (GCE)
    Altundal, Melis
    Uge, Ahmet
    Gok, Ozer
    Zeybek, Bulent
    ANALYTICAL LETTERS, 2021, 54 (15) : 2431 - 2451
  • [37] Determination of the herbicide paraquat using the new Ag-GO/CuO/GCE-modified glassy carbon electrode by differential pulse voltammetry
    Savary, Abdolrahman
    Yari, Abdollah
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (10) : 1987 - 1997
  • [38] THE APPLICATION OF DIFFERENTIAL PULSE VOLTAMMETRY AT THE GLASSY-CARBON ELECTRODE TO MULTIVITAMIN ANALYSIS
    BALLANTINE, J
    WOOLFSON, AD
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1980, 32 (05) : 353 - 356
  • [39] Determination of Catechol and Hydroquinone by Using Perilla frutescens Activated Carbon Modified Glassy Carbon Electrode
    Zheng, Meiqin
    Zhu, Jingjing
    Fan, Rongrong
    Wang, Yujie
    Lv, Zhaojun
    Han, Yongming
    Peng, Jun
    Zheng, Xinyu
    Lin, Ruiyu
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2020, 31 (01) : 25 - 32
  • [40] Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
    Mika, Jan
    Moreira, Josino C.
    Nemeckova, Andrea
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    MONATSHEFTE FUR CHEMIE, 2015, 146 (08): : 1211 - 1215