Direct kinetic loss analysis with hierarchy configuration of catalyst coated membrane in proton exchange membrane water electrolysis cell

被引:0
|
作者
He, Yunlong [1 ]
Feng, Suyang [1 ]
Chen, Hui [2 ]
Liu, Yun [1 ]
Shi, Xiaodong [1 ]
Rao, Peng [1 ]
Li, Jing [1 ]
Wu, Xiao [3 ]
Huang, Shuyi [3 ]
Li, Ke [3 ]
Wang, Hao [4 ]
Tian, Xinlong [1 ]
Kang, Zhenye [1 ,2 ]
机构
[1] Hainan Univ, Sch Marine Sci & Engn, State Key Lab Marine Resource Utilizat South China, Haikou 570228, Hainan, Peoples R China
[2] Jilin Univ, Coll Chem, State Key Lab Inorgan Synth & Preparat Chem, Changchun 130012, Peoples R China
[3] Natl Energy Grp Ledong Power Generat Co Ltd, Ledong 572539, Peoples R China
[4] Chinese Acad Sci, Beijing Key Lab Ion Liquids Clean Proc, State Key Lab Multiphase Complex Syst, CAS Key Lab Green Proc & Engn,Inst Proc Engn, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Water electrolysis; Hydrogen production; Electrode kinetics; Exchange current density; Degradation; PERFORMANCE; ELECTRODES;
D O I
10.1016/j.fuel.2024.133028
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electrode kinetics and degradation originations are key factors for proton exchange membrane water electrolyzer (PEMWE). However, it is hard to directly characterize these factors in an operating PEMWE, which is because of the coupled components. In this study, we fabricate a hierarchy configured catalyst coated membrane by implementing voltage sensing wires, which enables the in-situ characterization on each part in a PEMWE. Specially, using the integrated configuration, the voltages on anode and cathode electrode can be measured, which provides a chance for determining the kinetics of the electrode. The exchange current density and charge transfer coefficient could be easily obtained. This integrated hierarchy configuration provides a reliable pathway for developing usable catalyst materials and optimizing catalyst layers. The impedance on an inner component can also be measured, and we find that the kinetics are the main losses for both anode and cathode electrode, which contribute to more than 96.6% to electrode voltage loss in low current density range. Additionally, the technique can monitor the internal voltages in an operating PEMWE, which provides valuable data for performance change diagnostic and analysis. The hierarchy configuration enriches the PEMWE characterization methods, and has great promise for industrial applications due to its easy setup and high feasibility.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Experimental and numerical study of thermal coupling on catalyst-coated membrane for proton exchange membrane water electrolyzer
    Su, Chao
    Chen, Zhidong
    Wu, Zexuan
    Zhang, Jing
    Li, Kaiyang
    Hao, Junhong
    Kong, Yanqiang
    Zhang, Naiqiang
    APPLIED ENERGY, 2024, 357
  • [32] Progress on the anode catalysts for proton exchange membrane water electrolysis
    Zhang, Jiahao
    Yue, Qin
    CHINESE SCIENCE BULLETIN-CHINESE, 2022, 67 (24): : 2889 - 2905
  • [33] Development status and prospects of proton exchange membrane water electrolysis
    He Z.
    Shi C.
    Chen Z.
    Pan L.
    Huang Z.
    Zhang X.
    Zou J.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (09): : 4762 - 4773
  • [34] NiFeB anode catalyst for anion exchange membrane water electrolysis
    Faid, Alaa Y.
    Sunde, Svein
    MATERIALS LETTERS, 2022, 324
  • [35] Performance improvement induced by membrane treatment in proton exchange membrane water electrolysis cells
    Kang, Zhenye
    Wang, Min
    Yang, Yingjie
    Wang, Hao
    Liu, Yanrong
    Mo, Jingke
    Li, Jing
    Deng, Peilin
    Jia, Chunman
    Tian, Xinlong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (09) : 5807 - 5816
  • [36] Innovative Membrane Electrode Assembly (MEA) Fabrication for Proton Exchange Membrane Water Electrolysis
    Jung, Guo-Bin
    Chan, Shih-Hung
    Lai, Chun-Ju
    Yeh, Chia-Chen
    Yu, Jyun-Wei
    ENERGIES, 2019, 12 (21)
  • [37] Proton exchange membrane water electrolysis system-membrane electrode assembly with additive
    Yu, Jyun-Wei
    Jung, Guo-bin
    Su, Yi-Ju
    Yeh, Chia-Chen
    Kan, Min-Yu
    Lee, Che-Yu
    Lai, Chun-Ju
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (30) : 15721 - 15726
  • [38] Direct fabrication of gas diffusion cathode by pulse electrodeposition for proton exchange membrane water electrolysis
    Park, Hyanjoo
    Choe, Seunghoe
    Kim, Hoyoung
    Kim, Dong-Kwon
    Cho, GeonHee
    Park, YoonSu
    Jang, Jong Hyun
    Ha, Don-Hyung
    Ahn, Sang Hyun
    Kim, Soo-Kil
    APPLIED SURFACE SCIENCE, 2018, 444 : 303 - 311
  • [39] Anion Exchange Membrane Water Electrolysis from Catalyst Design to the Membrane Electrode Assembly
    Faid, Alaa Y.
    Sunde, Svein
    ENERGY TECHNOLOGY, 2022, 10 (09)
  • [40] Enhancing proton exchange membrane water electrolysis by building electron/proton pathways
    Zhu, Liyan
    Zhang, Hao
    Zhang, Aojie
    Tian, Tian
    Shen, Yuhan
    Wu, Mingjuan
    Li, Neng
    Tang, Haolin
    ADVANCED POWDER MATERIALS, 2024, 3 (04):