Design and performance evaluation of a mobile CO2 detector based on mid-infrared IBBCEAS

被引:0
|
作者
Chen, Jianbo [1 ]
Wang, Jianing [2 ]
Chang, Shuai [1 ,2 ,3 ]
Li, Pengbo [2 ]
Lin, Guanyu [2 ]
Tong, Shoufeng [1 ]
Li, Zhen [4 ,5 ]
Luo, Yinwei [4 ,5 ]
机构
[1] Changchun Univ Sci & Technol, Coll Optoelect Engn, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Beijing 130000, Peoples R China
[3] Henghui Optoelect Measurement Technol Jilin Co, Changchun, Peoples R China
[4] Univ Chinese Acad Sci, Natl Engn Lab VOCs Pollut Control Mat & Technol, Beijing 100049, Peoples R China
[5] Binzhou Inst Technol, Weiqiao UCAS Sci & Technol Pk, Binzhou 256606, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Greenhouse gases; Carbon dioxide; Mobile monitoring; IBBCEAS; Mid-infrared; ABSORPTION-SPECTROSCOPY; GAS SENSOR; NETWORK; SYSTEM; CH4;
D O I
10.1016/j.measurement.2025.116839
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Mobile detection and monitoring of CO2 are of extraordinary practical and scientific importance. Herein, we developed a CO2 detector for mobile monitoring platforms based on mid-infrared Incoherent Broadband CavityEnhanced Absorption Spectroscopy (IBBCEAS). The spectral transfer function and the stability calculation model for the mid-infrared broadband light source cavity were established based on the single-source dual-channel detector structure, and the calibration results showed good agreement with theoretical predictions. To meet the requirements of mobile monitoring and detection platforms, we implemented a novel design for gas intake into the chamber; the performed simulations demonstrated that the concentration equilibration time was reduced by a factor of 8.75. The optical and structural design of the detector, as well as performance evaluations conducted through relevant experiments, are given in detail. Experimental results indicated that the instrument exhibited a fluctuation of less than 9 parts per thousand under CO2 test conditions of 400 ppm (4.5 h) and 1600 ppm (4.5 h), indicating excellent stability. Allan variance calculations showed a detection limit better than 1.5 ppm with an integration time of 1 s, meeting the requirements for routine atmospheric measurements. Response time tests revealed a T50 response time of less than 3.3 s, demonstrating rapid detection of CO2 concentration changes. Field testing of the CO2 detector was conducted in an urban office park in Changchun, Jilin, China, effectively identifying variations in the local CO2 concentration along the measurement route, further confirming its potential for mobile monitoring applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Two Schemes for Generating Efficient Terahertz Waves in Nonlinear Optical Crystals with a Mid-Infrared CO2 Laser
    Rao Zhi-Ming
    Wang Xin-Bing
    Lu Yan-Zhao
    Zuo Du-Luo
    Wu Tao
    CHINESE PHYSICS LETTERS, 2011, 28 (07)
  • [42] An Iron Complex with a Bent, O-Coordinated CO2 Ligand Discovered by Femtosecond Mid-Infrared Spectroscopy
    Straub, Steffen
    Bruenker, Paul
    Lindner, Joerg
    Voehringer, Peter
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (18) : 5000 - 5005
  • [43] Spectrally resolved, 1D, mid-infrared imaging of temperature, CO2, and HCl in propellant flames
    McDonald, Austin
    Tancin, Ryan J.
    Goldenstein, Christopher S.
    APPLIED OPTICS, 2021, 60 (16) : 4524 - 4534
  • [44] Analysis of Optimized and Improved Low Cost Carbon Dioxide (CO2) Reflective Mid-Infrared Gas Sensor
    Salim, Mohd Rashidi
    Yaacob, Maslina
    Marcus, Tay Ching En
    David, Micheal
    Hussin, Nabihah
    Ibrahim, Mohd Haniff
    Azmi, Asrul Izam
    Ngajikin, Nor Hafizah
    Dooly, Gerard
    Lewis, Elfed
    JURNAL TEKNOLOGI, 2015, 73 (03):
  • [45] Compact Hollow Waveguide Mid-Infrared Gas Sensor For Simultaneous Measurements of Ambient CO2 and Water Vapor
    Wu, Tao
    Kong, Weiping
    Wang, Mengyu
    Wu, Qiang
    Chen, Weidong
    Ye, Chenwen
    Hu, Rongjing
    He, Xingdao
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2020, 38 (16) : 4580 - 4587
  • [46] Real-Time Exhaled CO2 Gas Measurement Using a Mid-Infrared Hollow Waveguide Fiber
    Ma Shuai
    Wu Tao
    Sun Chenglin
    Zhou Tao
    He Xingdao
    ACTA OPTICA SINICA, 2020, 40 (11)
  • [47] Mid-infrared CO2 sensor with blended absorption features for non-uniform laminar premixed flames
    Wang, Zhenhai
    Wang, Weitian
    Ma, Liuhao
    Fu, Pengfei
    Ren, Wei
    Chao, Xing
    APPLIED PHYSICS B-LASERS AND OPTICS, 2022, 128 (02):
  • [48] Rapid and precise measurement of atmospheric CO2 and its isotopic ratios using a mid-infrared gas sensor
    Cui, Xiaojuan
    Cui, Xiaohan
    Zhu, Qizhi
    Yin, Shuaikang
    Shi, Xin
    Zhang, Lewen
    Yu, Benli
    Hong, Yang
    Chen, Weidong
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 430
  • [49] Measurement of CO Concentration in Combustion Field Based on Mid-Infrared Absorption Spectroscopy
    Peng Y.
    Kan R.
    Xu Z.
    Xia H.
    Nie W.
    Zhang B.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2018, 45 (09):
  • [50] Quantum-dot-based single-photon avalanche detector for mid-infrared applications
    Zavvari, Mahdi
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2015, 32 (05) : 737 - 742