Design and performance evaluation of a mobile CO2 detector based on mid-infrared IBBCEAS

被引:0
|
作者
Chen, Jianbo [1 ]
Wang, Jianing [2 ]
Chang, Shuai [1 ,2 ,3 ]
Li, Pengbo [2 ]
Lin, Guanyu [2 ]
Tong, Shoufeng [1 ]
Li, Zhen [4 ,5 ]
Luo, Yinwei [4 ,5 ]
机构
[1] Changchun Univ Sci & Technol, Coll Optoelect Engn, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Beijing 130000, Peoples R China
[3] Henghui Optoelect Measurement Technol Jilin Co, Changchun, Peoples R China
[4] Univ Chinese Acad Sci, Natl Engn Lab VOCs Pollut Control Mat & Technol, Beijing 100049, Peoples R China
[5] Binzhou Inst Technol, Weiqiao UCAS Sci & Technol Pk, Binzhou 256606, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Greenhouse gases; Carbon dioxide; Mobile monitoring; IBBCEAS; Mid-infrared; ABSORPTION-SPECTROSCOPY; GAS SENSOR; NETWORK; SYSTEM; CH4;
D O I
10.1016/j.measurement.2025.116839
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Mobile detection and monitoring of CO2 are of extraordinary practical and scientific importance. Herein, we developed a CO2 detector for mobile monitoring platforms based on mid-infrared Incoherent Broadband CavityEnhanced Absorption Spectroscopy (IBBCEAS). The spectral transfer function and the stability calculation model for the mid-infrared broadband light source cavity were established based on the single-source dual-channel detector structure, and the calibration results showed good agreement with theoretical predictions. To meet the requirements of mobile monitoring and detection platforms, we implemented a novel design for gas intake into the chamber; the performed simulations demonstrated that the concentration equilibration time was reduced by a factor of 8.75. The optical and structural design of the detector, as well as performance evaluations conducted through relevant experiments, are given in detail. Experimental results indicated that the instrument exhibited a fluctuation of less than 9 parts per thousand under CO2 test conditions of 400 ppm (4.5 h) and 1600 ppm (4.5 h), indicating excellent stability. Allan variance calculations showed a detection limit better than 1.5 ppm with an integration time of 1 s, meeting the requirements for routine atmospheric measurements. Response time tests revealed a T50 response time of less than 3.3 s, demonstrating rapid detection of CO2 concentration changes. Field testing of the CO2 detector was conducted in an urban office park in Changchun, Jilin, China, effectively identifying variations in the local CO2 concentration along the measurement route, further confirming its potential for mobile monitoring applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy
    Dong M.
    Zhong G.-Q.
    Miao S.-Z.
    Zheng C.-T.
    Wang Y.-D.
    Zheng, Chuan-tao (zhengchuantao@jlu.edu.cn), 2018, Springer Verlag (14): : 119 - 123
  • [12] Terahertz Generation in Nonlinear Crystals with Mid-Infrared CO2 Laser
    Lu Yan-Zhao
    Wang Xin-Bing
    Miao Liang
    Zuo Du-Luo
    Cheng Zu-Hai
    CHINESE PHYSICS LETTERS, 2011, 28 (03)
  • [13] DOPING SUPERLATTICES BASED ON INSB FOR MID-INFRARED DETECTOR APPLICATIONS
    PHILLIPS, CC
    APPLIED PHYSICS LETTERS, 1990, 56 (02) : 151 - 153
  • [14] High-temperature superconductor based mid-infrared detector
    Kumar, Ankit
    Panna, Dmitry
    Bouscher, Shlomi
    Natale, Gabriel
    Plisson, Vincent
    Burch, Kenneth S.
    Kanigel, Amit
    Hayat, Alex
    OPTICS COMMUNICATIONS, 2025, 579
  • [15] Evaluation of baking performance by means of mid-infrared imaging
    Takacs, Ronny
    Jovicic, Vojislav
    Zbogar-Rasic, Ana
    Geier, Dominik
    Delgado, Antonio
    Becker, Thomas
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2020, 61
  • [16] High-Performance Uncooled Mid-Infrared Detector Based on a Polycrystalline PbSe/CdSe Heterojunction
    Qiu, Jijun
    Su, Leisheng
    McDowell, Lance L.
    Phan, Quang
    Liu, Yun
    Zhang, Guodong
    Yang, Yiming
    Shi, Zhisheng
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (20) : 24541 - 24548
  • [17] A CMOS Compatible Pyroelectric Mid-Infrared Detector Based on Aluminium Nitride
    Ranacher, Christian
    Consani, Cristina
    Tortschanoff, Andreas
    Rauter, Lukas
    Holzmann, Dominik
    Fleury, Clement
    Stocker, Gerald
    Fant, Andrea
    Schaunig, Herbert
    Irsigler, Peter
    Grille, Thomas
    Jakoby, Bernhard
    SENSORS, 2019, 19 (11):
  • [18] On-Chip Dispersion Spectroscopy of CO2 Using a Mid-Infrared Microring Resonator
    Briano, Floria Ottonello
    Errando-Herranz, Carlos
    Gylfason, Kristinn B.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [19] Measurement of CO2 Isotopologue Ratios Using a Hollow Waveguide-Based Mid-Infrared Dispersion Spectrometer
    Zhang, Haojie
    Wu, Tao
    Wu, Qiang
    Chen, Weidong
    Ye, Chenwen
    Wang, Mengyu
    He, Xingdao
    ANALYTICAL CHEMISTRY, 2023, 95 (50) : 18479 - 18486
  • [20] A comparison of tissue effects produced by thulium fiber, CO2, and mid-infrared diode laser
    Lemberg, Vladimir
    Rozhetskin, Dmitry
    Jadczak, Chris
    LASERS IN SURGERY AND MEDICINE, 2008, : 58 - 58