Lagrangian analysis of fluid transport in pulsatile post-stenotic flows

被引:0
|
作者
Han, Xing [1 ]
Zhang, Kai [1 ]
机构
[1] Harbin Inst Technol, Ctr Turbulence Control, Shenzhen 518055, Guangdong, Peoples R China
关键词
Stenotic flows; Mass transfer; Lagrangian analysis; Pathline extension; Pulsatile flows; Transportation effectiveneess; DIRECT NUMERICAL-SIMULATION; MASS-TRANSFER; ARTERIAL-STENOSIS; STENOTIC FLOWS; UNSTEADY-FLOW; MODELS; BLOOD;
D O I
10.1016/j.expthermflusci.2024.111342
中图分类号
O414.1 [热力学];
学科分类号
摘要
A comprehensive experimental study was performed to characterize the fluid transportation processes in pulsatile post-stenotic flows. This study aims to understand the effect of pulsatility on the transportation dynamics of post-stenotic flows and to establish a non-dimensional number to quantify transportation effectiveness in these flows. Two-dimensional particle tracking velocimetry measurements were conducted in a close flow loop with a symmetric stenosis model. A pathline extension algorithm is then applied to the obtained Lagrangian data, such that fluid parcels are continuously tracked as they flow through the region of interest. Pulsatile flows at Reynolds numbers Rem = 1000, 2000, 4000, Strouhal number St = 0.05, 0.1, 0.15 and amplitude ratio 7 = 0.4 and 0.8 are systematically investigated to understand the influence of pulsatility on the transport and mixing dynamics. The flow structures, such as the formation and evaluation of vortex rings, Kelvin-Helmoltz instabilities, jet meandering and breakdown, are clearly revealed by the lifespan parcel trajectories and the particle residence time (PRT). These structures are closely related to the transportation behaviours of the post-stenotic flows. Using the obtained Lagrangian results, the transportation effectiveness of the post-stenotic flows is further quantified by the depletion efficiency. The results demonstrate that while post-stenotic flows transport most residual fluids under a higher amplitude ratio, the depletion efficiency itself is insensitive to the amplitude ratio. The flow system operates more efficiently with high pulsatile frequencies (St = 0.8). Additionally, a transportation effectiveness parameter, Te , is defined to evaluate the transport performance by comparing the transportation efficiency to the pressure drop. The Te value is optimized at a high pulsatile frequency (St = 0.8) and a low amplitude ratio (7 = 0.4), with Te being up to twice as high as its counterpart in the steady flow.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] STABILITY OF FLOW PATTERNS IN THE INVIVO POST-STENOTIC VELOCITY-FIELD
    HUTCHISON, KJ
    KARPINSKI, E
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (04): : 269 - 275
  • [32] The relationship between post-stenotic peak systolic velocity and endorgan resistance
    Bude, RO
    Rubin, JM
    RADIOLOGY, 1998, 209P : 459 - 459
  • [33] EFFECT OF NITROGLYCERIN AND ANGIOPLASTY ON POST-STENOTIC CORONARY-ARTERY DIAMETER
    BERNAUER, R
    SCHULZ, W
    KALTENBACH, M
    KOBER, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 12 - 12
  • [34] Lagrangian approach for modal analysis of fluid flows
    Shinde, Vilas J.
    Gaitonde, Datta, V
    JOURNAL OF FLUID MECHANICS, 2021, 928 (928)
  • [35] Inflammatory and injury signals released from the post-stenotic human kidney
    Eirin, Alfonso
    Gloviczki, Monika L.
    Tang, Hui
    Goessl, Mario
    Jordan, Kyra L.
    Woollard, John R.
    Lerman, Amir
    Grande, Joseph P.
    Textor, Stephen C.
    Lerman, Lilach O.
    EUROPEAN HEART JOURNAL, 2013, 34 (07) : 540 - +
  • [36] AUTOREGRESSIVE SPECTRAL ESTIMATION OF POST-STENOTIC BLOOD-FLOW DISTURBANCES
    GIDDENS, DP
    KITNEY, RI
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (04): : 401 - 404
  • [37] STENOSIS OF THE AORTIC ISTHMUS WITH AN ANEURYSM OF AN ARTERIA LUSORIA WITH POST-STENOTIC ORIGIN
    GOEBEL, N
    TURINA, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1981, 135 (03): : 360 - 363
  • [38] High-Frequency Fluctuations in Post-stenotic Patient Specific Carotid Stenosis Fluid Dynamics: A Computational Fluid Dynamics Strategy Study
    Viviana Mancini
    Aslak W. Bergersen
    Jan Vierendeels
    Patrick Segers
    Kristian Valen-Sendstad
    Cardiovascular Engineering and Technology, 2019, 10 : 277 - 298
  • [39] Perturbation analysis for pulsatile flow of Carreau fluid through tapered stenotic arteries
    Sankar, D. S.
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2016, 9 (04)
  • [40] High-Frequency Fluctuations in Post-stenotic Patient Specific Carotid Stenosis Fluid Dynamics: A Computational Fluid Dynamics Strategy Study
    Mancini, Viviana
    Bergersen, Aslak W.
    Vierendeels, Jan
    Segers, Patrick
    Valen-Sendstad, Kristian
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (02) : 277 - 298