Lagrangian analysis of fluid transport in pulsatile post-stenotic flows

被引:0
|
作者
Han, Xing [1 ]
Zhang, Kai [1 ]
机构
[1] Harbin Inst Technol, Ctr Turbulence Control, Shenzhen 518055, Guangdong, Peoples R China
关键词
Stenotic flows; Mass transfer; Lagrangian analysis; Pathline extension; Pulsatile flows; Transportation effectiveneess; DIRECT NUMERICAL-SIMULATION; MASS-TRANSFER; ARTERIAL-STENOSIS; STENOTIC FLOWS; UNSTEADY-FLOW; MODELS; BLOOD;
D O I
10.1016/j.expthermflusci.2024.111342
中图分类号
O414.1 [热力学];
学科分类号
摘要
A comprehensive experimental study was performed to characterize the fluid transportation processes in pulsatile post-stenotic flows. This study aims to understand the effect of pulsatility on the transportation dynamics of post-stenotic flows and to establish a non-dimensional number to quantify transportation effectiveness in these flows. Two-dimensional particle tracking velocimetry measurements were conducted in a close flow loop with a symmetric stenosis model. A pathline extension algorithm is then applied to the obtained Lagrangian data, such that fluid parcels are continuously tracked as they flow through the region of interest. Pulsatile flows at Reynolds numbers Rem = 1000, 2000, 4000, Strouhal number St = 0.05, 0.1, 0.15 and amplitude ratio 7 = 0.4 and 0.8 are systematically investigated to understand the influence of pulsatility on the transport and mixing dynamics. The flow structures, such as the formation and evaluation of vortex rings, Kelvin-Helmoltz instabilities, jet meandering and breakdown, are clearly revealed by the lifespan parcel trajectories and the particle residence time (PRT). These structures are closely related to the transportation behaviours of the post-stenotic flows. Using the obtained Lagrangian results, the transportation effectiveness of the post-stenotic flows is further quantified by the depletion efficiency. The results demonstrate that while post-stenotic flows transport most residual fluids under a higher amplitude ratio, the depletion efficiency itself is insensitive to the amplitude ratio. The flow system operates more efficiently with high pulsatile frequencies (St = 0.8). Additionally, a transportation effectiveness parameter, Te , is defined to evaluate the transport performance by comparing the transportation efficiency to the pressure drop. The Te value is optimized at a high pulsatile frequency (St = 0.8) and a low amplitude ratio (7 = 0.4), with Te being up to twice as high as its counterpart in the steady flow.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] EXTRACTION AND CHARACTERIZATION OF UNDERLYING VELOCITY WAVEFORMS IN POST-STENOTIC FLOW
    KITNEY, RI
    GIDDENS, DP
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1982, 129 (09): : 651 - 662
  • [23] EXPERIMENTAL PRODUCTION OF POST-STENOTIC DILATATION IN THE CAROTID ARTERIES OF RABBITS
    IMATAKA, K
    SEKI, A
    TOMONO, S
    TAKAHASHI, N
    FUJII, J
    JAPANESE HEART JOURNAL, 1981, 22 (01): : 127 - 133
  • [24] Analysis of the formation mechanism and occurrence possibility of Post-Stenotic Dilatation of the aorta by CFD approach
    Zhang, Xuelan
    Luo, Mingyao
    Fang, Kun
    Li, Jiehua
    Peng, Yuan
    Zheng, Liancun
    Shu, Chang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 194 (194)
  • [25] Adult Coarctation of Aorta With Post-Stenotic Calcified Aortic Aneurysms
    Jayavelan, Ramkumar
    Saldanha, Richard
    Muthukumar, Siva
    Nerlikar, Amrutraj Gopalrao
    Karthekeyan, Ranjith
    Vakamudi, Mahesh
    Thanikachalam, Sadagopan
    ANNALS OF THORACIC SURGERY, 2011, 91 (03): : 930 - 930
  • [26] POST-STENOTIC DILATATION OF PULMONARY ARTERY SIMULATING AORTIC ANEURYSM
    MARTINEZ.JI
    SOUTHERN MEDICAL JOURNAL, 1966, 59 (11) : 1335 - &
  • [27] Kinematic and dynamic characteristics of pulsatile flows in stenotic vessels
    Hung, TK
    Tsai, TMC
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1997, 123 (03): : 247 - 259
  • [28] POST-STENOTIC VASCULAR DILATATION - CONFIRMATION OF AN OLD HYPOTHESIS BY A NEW METHOD
    KLINE, JL
    GIMENEZ, JL
    MALONEY, RJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1962, 44 (06): : 738 - &
  • [29] The relationship between post-stenotic peak systolic velocity and vascular compliance
    Bude, RO
    Rubin, JM
    RADIOLOGY, 1998, 209P : 340 - 340
  • [30] Post-Stenotic Recirculating Flow May Cause Hemodynamic Perforator Infarction
    Kim, Bum Joon
    Ha, Hojin
    Huh, Hyung Kyu
    Kim, Guk Bae
    Kim, Jong S.
    Kim, Namkug
    Lee, Sang-Joon
    Kang, Dong-Wha
    Kwon, Sun U.
    JOURNAL OF STROKE, 2016, 18 (01) : 66 - 72