One-step copper deposition-induced signal amplification for multiplex bacterial infection diagnosis on a lateral flow immunoassay device

被引:1
|
作者
Chien, Yuh-Shiuan [1 ]
Tsai, Tsung-Ting [2 ,3 ]
Lin, Jia-Hui [4 ]
Chang, Chien-Cheng [1 ]
Chen, Chien-Fu [1 ,5 ]
机构
[1] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[2] Chang Gung Mem Hosp, Dept Orthopaed Surg, Taoyuan 333, Taiwan
[3] Chang Gung Univ, Coll Med, Taoyuan 333, Taiwan
[4] Natl Univ Kaohsiung, Dept Appl Chem, Kaohsiung 811, Taiwan
[5] Natl Taiwan Univ, Grad Sch Adv Technol, Taipei 106, Taiwan
来源
关键词
Lateral flow immunoassay; Copper deposition; Point-of-care device; One-step signal amplification; Staphylococcus aureus; Pseudomonas aeruginosa; PAPER; NANOPARTICLES;
D O I
10.1016/j.bios.2024.116849
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lateral flow immunoassay (LFIA) is predominant in rapid diagnostic tests owing to its cost-effectiveness and operational simplicity. However, the conventional LFIA exhibits limited sensitivity and is susceptible to human variance for the result readout, impacting result interpretation. In this study, we introduced a novel one-step copper deposition-induced signal amplification lateral flow immunoassay (osa-LFIA) that markedly enhances the detection sensitivity for Staphylococcus aureus (protein A) and Pseudomonas aeruginosa (exotoxin A). Utilizing gold nanoparticles (AuNPs) as a catalyst, this approach employs ascorbic acid to reduce Cu2+ to Cu-0, depositing on AuNPs at the test line and amplifying the signal. A user-friendly design features a three-dimensional paper structure incorporating pre-dried reagents, enabling a streamlined, efficient testing process. The osa-LFIA significantly lowers detection limits to 3 ng mL(-1) for protein A and 10 ng mL(-1) for exotoxin A, offering a tenfold improvement over conventional LFIA. Additionally, we developed a portable grayscale detection device, achieving less than 10% error in quantitative analysis compared to the data acquired and analyzed in the lab. This entire process, from detection to signal amplification, is completed in just 20 min. For the clinical trial, we utilized the osa-LFIA to test synovial fluid samples infected with Staphylococcus aureus. We also successfully detected different concentrations of the exotoxin A in parallel, with a recovery value of 96%-110%. Our findings demonstrate the osa-LFIA's potential as a rapid, highly sensitive, and simple-to-use diagnostic tool for detecting various pathogens, significantly advancing the field of rapid diagnostic testing.
引用
收藏
页数:10
相关论文
共 42 条
  • [21] Amplification-free DNA Sensor for the One-Step Detection of the Hepatitis B Virus Using an Automated Paper-Based Lateral Flow Electrochemical Device
    Srisomwat, Chawin
    Yakoh, Abdulhadee
    Chuaypen, Natthaya
    Tangkijvanich, Pisit
    Vilaivan, Tirayut
    Chailapakul, Orawon
    ANALYTICAL CHEMISTRY, 2021, 93 (05) : 2879 - 2887
  • [22] A one-step reverse transcription recombinase polymerase amplification assay for lateral flow-based visual detection of PVY
    Cassedy, Arabelle
    Della Bartola, Michele
    Parle-McDermott, Anne
    Mullins, Ewen
    O'Kennedy, Richard
    ANALYTICAL BIOCHEMISTRY, 2022, 642
  • [23] One-Step Reverse-Transcription Recombinase Polymerase Amplification Using Lateral Flow Strips for the Detection of Coxsackievirus A6
    Xie, Jia
    Yang, Xiaohan
    Duan, Lei
    Chen, Keyi
    Liu, Pan
    Zhan, Wenli
    Zhang, Changbin
    Zhao, Hongyu
    Wei, Mengru
    Tang, Yuan
    Luo, Mingyong
    FRONTIERS IN MICROBIOLOGY, 2021, 12
  • [24] One-step signal amplified lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A (BPA) in aqueous samples
    Mei, Zhanlong
    Qu, Wei
    Deng, Yi
    Chu, Huaqin
    Cao, Jinxuan
    Xue, Feng
    Zheng, Lei
    El-Nezamic, Hani Said
    Wu, Yucheng
    Chen, Wei
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 457 - 461
  • [25] A Highly Specific and Sensitive Hepatitis C Virus Antigen Enzyme Immunoassay for One-Step Diagnosis of Viremic Hepatitis C Virus Infection
    Hu, Ke-Qin
    Cui, Wei
    HEPATOLOGY, 2016, 64 (02) : 415 - 424
  • [26] Universal All-In-One Lateral Flow Immunoassay with Triple Signal Amplification for Ultrasensitive and Simple Self-Testing of Treponema pallidum Antibodies
    Dong, Tao
    Sun, Guangze
    Liu, Aihua
    ANALYTICAL CHEMISTRY, 2024, 96 (44) : 17537 - 17545
  • [27] A gold nanoparticle-based four-color proximity immunoassay for one-step, multiplexed detection of protein biomarkers using ribonuclease H signal amplification
    Xu, Jiayao
    Shi, Ming
    Chen, Wenting
    Huang, Yong
    Fang, Lina
    Yao, Lifang
    Zhao, Shulin
    Chen, Zhen-Feng
    Liang, Hong
    CHEMICAL COMMUNICATIONS, 2018, 54 (22) : 2719 - 2722
  • [28] A Highly Specific and Sensitive Hepatitis C Virus Antigens Enzyme Immunoassay (HCV-Ags EIA) for One-step Diagnosis of HCV Infection
    Hu, Ke-Qin
    Cui, Wei
    HEPATOLOGY, 2015, 62 : 251A - 252A
  • [29] Performance of point-of-care diagnosis of AIDS: label-free one-step-immunoassay vs. lateral flow assay
    Kwon, J. -H.
    Kim, H. -T.
    Sim, S. J.
    Cha, Y. J.
    Lee, J.
    ANALYST, 2018, 143 (04) : 936 - 942
  • [30] Ultrasensitive detection of Mycobacterium tuberculosis by a rapid and specific probe-triggered one-step, simultaneous DNA hybridization and isothermal amplification combined with a lateral flow dipstick
    Jaroenram, Wansadaj
    Kampeera, Jantana
    Arunrut, Narong
    Sirithammajak, Sarawut
    Jaitrong, Sarinya
    Boonnak, Kobporn
    Khumwan, Pakapreud
    Prammananan, Therdsak
    Chaiprasert, Angkana
    Kiatpathomchai, Wansika
    SCIENTIFIC REPORTS, 2020, 10 (01)