Fixation of femoral neck fractures using divergent versus parallel cannulated screws

被引:2
|
作者
Papanastassiou I.D. [1 ,2 ]
Mavrogenis A.F. [2 ]
Kokkalis Z.T. [2 ]
Nikolopoulos K. [2 ]
Skourtas K. [1 ]
Papagelopoulos P.J. [2 ]
机构
[1] First Department of Orthopedics, KAT Hospital, Athens
[2] First Department of Orthopedics, Athens University Medical School, Athens
关键词
Cannulated screws; Divergent; Femoral neck fractures; Internal fixation; Parallel; Stainless steel;
D O I
10.1615/JLongTermEffMedImplants.v21.i1.50
中图分类号
学科分类号
摘要
Controversy exists regarding the optimal method of internal fixation in femoral neck fractures. Biomechanical data suggest that calcar fixation is superior to central screws placement. We propose a divergent technique for placing 3 cannulated stainless steel screws engaging the calcar femorale. Fiftytwo patients admitted to our institution for a femoral neck fracture were treated with the divergent screw technique, over a 7-year period. Four patients were deceased and 4 were lost to follow-up. Of the remaining 44 patients there were 10 males and 34 females, aged from 33 to 78 years (mean, 58 years). All patients were operated on by the same surgeon and were followed-up for a minimum of 2 years (mean: 33.6 months, range: 2-6 years). Twenty-four patients sustained a non-displaced fracture (Garden I-II) and 20 sustained a displaced fracture (Garden III-IV) of the femoral neck. Mean Harris hip score (HHS) was 89.6 points. Avascular necrosis was evident in 4 patients (9%) with displaced fractures. Non-unions or failed internal fixations were not encountered. There was a significant difference in the HHS, in favor of the divergent group (P = 0.006), while more complications were encountered in the parallel group including 6 cases with non-union. In conclusion, parallel screw placement is not critical for an excellent clinical outcome. Our proposed fixation method using 3 screws that diverge and lie in diff erent coronal planes (1 engaging the calcar femorale) with a free-hand technique may off er enhanced fixation. Biomechanical data along with larger clinical studies are needed to establish our proposed method. © 2011 by Begell House, Inc.
引用
收藏
页码:63 / 69
页数:6
相关论文
共 50 条
  • [31] What is the Fate of Undisplaced Femoral Neck Fractures Treated With Cannulated Screws?
    Slullitel, Pablo A.
    Latallade, Valentino
    Huespe, Ivan A.
    Lucero-Viviani, Nicolas
    Buttaro, Martin A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (01): : 111 - 117
  • [32] Femoral neck system versus multiple cannulated screws for the fixation of Pauwels classification type II femoral neck fractures in older female patients with low bone mass
    Soon-Chin Yeoh
    Wen-Tien Wu
    Cheng-Huan Peng
    Ting-Kuo Yao
    Chia-Ming Chang
    Kuan-Lin Liu
    Tzai-Chiu Yu
    Ing-Ho Chen
    Jen-Hung Wang
    Kuang-Ting Yeh
    BMC Musculoskeletal Disorders, 25
  • [33] Non-cannulated versus cannulated cancellous screws for the internal fixation of femoral neck fractures in osteoporotic patients: A single-blind randomized clinical trial
    Sadeghpour, Alireza
    Mahdipour, Shahab
    Sales, Jafar Ghanjpour
    Aslani, Hossein
    Moharrami, Mohammad Reza
    Alizadeh, Hadi
    JOURNAL OF ORTHOPAEDICS, 2024, 51 : 32 - 38
  • [34] Multiple cannulated screw fixation of young femoral neck fractures
    Kim, Joo Yong
    Kong, Gyu Min
    Park, Dae Hyun
    Kim, Dae Yoo
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (06) : 1517 - 1520
  • [35] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [36] Is there an increased risk for subtrochanteric stress fracture with the Femoral Neck System versus multiple cannulated screws fixation?
    Hsu, Megan R.
    Shu, Henry T.
    Luksameearunothai, Kitchai
    Margalit, Adam
    Yu, Andrew T.
    Hasenboehler, Erik A.
    Shafiq, Babar
    JOURNAL OF ORTHOPAEDICS, 2022, 30 : 127 - 133
  • [37] Femoral neck system versus cannulated screws for fixation of femoral neck fracture in young adults: a systematic review and meta-analysis
    Lu, Yao
    Huang, Zhilong
    Xu, Yibo
    Huang, Qiang
    Ren, Cheng
    Li, Ming
    Li, Zhong
    Sun, Liang
    Xue, Hanzhong
    Zhang, Kun
    Wang, Qian
    Ma, Teng
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (08): : 5480 - +
  • [38] Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation
    Li, Jiantao
    Wang, Menglin
    Zhou, Jianfeng
    Han, Lin
    Zhang, Hao
    Li, Chen
    Li, Lianting
    Hao, Ming
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [39] A prediction model for osteonecrosis of femoral head after internal fixation with multiple cannulated compression screws for adult femoral neck fractures
    Jin, Zhang
    Chen, Luo
    Wang, Dafeng
    Ye, Yayun
    Fu, Jiaxing
    Yang, Zhifan
    He, Baoqiang
    JOINT DISEASES AND RELATED SURGERY, 2024, 35 (01): : 20 - 26
  • [40] Treatment of Delbet II/III Pediatric Femoral Neck Fractures With Proximal Femoral Locking Plate Versus Cannulated Screws
    Haider, Shamrez
    Harris, Timothy J.
    Turner, Alexander C.
    Podeszwa, David A.
    Hartman, Courtney A.
    Morris, William Z.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : 213 - 220