Experimental study on thermal performance of a single-phase immersion cooling unit for high-density computing power data center

被引:1
|
作者
Sun, Xinshan [1 ]
Liu, Zhan [1 ]
Ji, Shenrui [1 ]
Yuan, Kaifeng [1 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Intelligent Construct & Hlth Operat, Xuzhou 221116, Peoples R China
关键词
Single-phase immersion cooling; High-density computing power; Data center; Thermal performance; Power usage effectiveness;
D O I
10.1016/j.ijheatfluidflow.2024.109735
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional air-cooling systems cannot meet special requirements of high-density computing power data centers (DCs). The single-phase immersion cooling (SPIC) is considered as one of the best ways to effectively cool highdensity computing power DC cabinets. In this study, a SPIC unit was experimentally investigated with dielectric fluid Noah 3000D under a designed heat load of 20 kW. The impact of the cooling water flow rate qv2 on the thermal characteristics, flow resistance and power consumption of the SPIC unit were investigated. The results show that the temperatures of both the coolant and cooling water decrease with the increase of qv2, but the temperature difference of coolant increases with the increase of qv2. An increase in coolant temperature difference means an increase in temperature non-uniformity. The increase in qv2 also leads to an increase in system flow resistance. In this experiment, the pressure loss of the heat exchanger and pipelines on the coolant side, account for about 56 % and 44 %, respectively. The power usage effectiveness of the cooling system in DC (cPUE) and coefficient of performance (COP) of the SPIC unit vary in the range of 1.08-1.09 and 5.69-7.21, respectively. Moreover, it is found that simply increasing qv2 cannot significantly improve the heat exchange of SPIC units, but will increase system's energy consumption to a certain extent. The present study mainly focuses on the laboratory experimental test on the SPIC unit, and the related conclusions are significant to the design and operation of SPIC units in high-density computing power DCs.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Evaluation of energy, economic, and pollution emission for single-phase immersion cooling data center with different economizers
    Liu, Shengchun
    Guo, Shentong
    Sun, Haiwang
    Xu, Zhiming
    Li, Xueqiang
    Wang, Xinyue
    APPLIED THERMAL ENGINEERING, 2025, 260
  • [22] Experimental and numerical analysis of the thermal behaviour of a single-phase immersion-cooled data centre
    Taddeo, Paolo
    Romani, Joaquim
    Summers, Jon
    Gustafsson, Jonas
    Martorell, Ingrid
    Salom, Jaume
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [23] Design of a single-phase immersion cooling system through experimental and numerical analysis
    Cheng, Chin-Chi
    Chang, Po-Chun
    Li, Hsing-Chieh
    Hsu, Fu-, I
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
  • [24] The Use of Single-Phase Immersion Cooling by Using Two Types of Dielectric Fluid for Data Center Energy Savings
    Pambudi N.A.
    Yusuf A.M.
    Sarifudin A.
    Energy Engineering: Journal of the Association of Energy Engineering, 2022, 119 (01): : 275 - 286
  • [25] Numerical Investigation on Heat Transfer Performance of a Single-Phase Immersion Cooling System
    Jin, Shuqi
    Yin, Renjie
    Li, Yuting
    Tao, Wen-Quan
    ADVANCES IN COMPUTATIONAL HEAT AND MASS TRANSFER, ICCHMT 2023, VOL 1, 2024, : 301 - 311
  • [26] Experimental investigation of a data-centre cooling system using a new single-phase immersion/liquid technique
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 45
  • [27] Experimental study of serpentine channels immersion cooling for lithium-ion battery thermal management using single-phase dielectric fluid
    Febriyanto, Rusdi
    Ariyadi, Hifni Mukhtar
    Pranoto, Indro
    Rahman, Muhammad Aulia
    JOURNAL OF ENERGY STORAGE, 2024, 97
  • [28] Thermal Management of Li-Ion Batteries With Single-Phase Liquid Immersion Cooling
    Sundin, David W.
    Sponholtz, Sebastian
    IEEE OPEN JOURNAL OF VEHICULAR TECHNOLOGY, 2020, 1 : 82 - 92
  • [29] Comprehensive feasibility study on metal foam use in single-phase immersion cooling for battery thermal management system
    Choi, Hongseok
    Jun, Yongjoo
    Chun, Heechan
    Lee, Hoseong
    APPLIED ENERGY, 2024, 375
  • [30] Experimental Study of Single-Phase Spray Cooling in a Vibrating Environment
    Chen, Xinwen
    Du, Aimin
    Zhu, Zhongpan
    Han, Yeyang
    Li, Hang
    Liang, Kun
    Tongji Daxue Xuebao/Journal of Tongji University, 2024, 52 : 51 - 56