Experimental study on thermal performance of a single-phase immersion cooling unit for high-density computing power data center

被引:1
|
作者
Sun, Xinshan [1 ]
Liu, Zhan [1 ]
Ji, Shenrui [1 ]
Yuan, Kaifeng [1 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Intelligent Construct & Hlth Operat, Xuzhou 221116, Peoples R China
关键词
Single-phase immersion cooling; High-density computing power; Data center; Thermal performance; Power usage effectiveness;
D O I
10.1016/j.ijheatfluidflow.2024.109735
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional air-cooling systems cannot meet special requirements of high-density computing power data centers (DCs). The single-phase immersion cooling (SPIC) is considered as one of the best ways to effectively cool highdensity computing power DC cabinets. In this study, a SPIC unit was experimentally investigated with dielectric fluid Noah 3000D under a designed heat load of 20 kW. The impact of the cooling water flow rate qv2 on the thermal characteristics, flow resistance and power consumption of the SPIC unit were investigated. The results show that the temperatures of both the coolant and cooling water decrease with the increase of qv2, but the temperature difference of coolant increases with the increase of qv2. An increase in coolant temperature difference means an increase in temperature non-uniformity. The increase in qv2 also leads to an increase in system flow resistance. In this experiment, the pressure loss of the heat exchanger and pipelines on the coolant side, account for about 56 % and 44 %, respectively. The power usage effectiveness of the cooling system in DC (cPUE) and coefficient of performance (COP) of the SPIC unit vary in the range of 1.08-1.09 and 5.69-7.21, respectively. Moreover, it is found that simply increasing qv2 cannot significantly improve the heat exchange of SPIC units, but will increase system's energy consumption to a certain extent. The present study mainly focuses on the laboratory experimental test on the SPIC unit, and the related conclusions are significant to the design and operation of SPIC units in high-density computing power DCs.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] SINGLE-PHASE IMMERSION COOLING STUDY OF A HIGH-DENSITY STORAGE SYSTEM
    Karajgikar, Saket
    Kidger, Jasper
    Shaw, Andrew
    Edmunds, Neil
    Mulay, Veerendra
    PROCEEDINGS OF ASME 2022 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2022, 2022,
  • [2] Experimental study of the performance of liquid cooling tank used for single-phase immersion cooling data center
    Li, Xueqiang
    Guo, Shentong
    Sun, Haiwang
    Yin, Shen
    Liu, Shengchun
    Wang, Zhiming
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [3] Thermal Performance of Single-Phase and Two-Phase Immersion Cooling in Data Center
    Liu, Chun-Kai
    Chang, Tan-Yi
    2022 17TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT), 2022,
  • [4] Server performance optimization for single-phase immersion cooling data center
    Li, Xueqiang
    Xu, Zhiming
    Liu, Shengchun
    Zhang, Xinyu
    Sun, Haiwang
    APPLIED THERMAL ENGINEERING, 2023, 224
  • [5] Performance improvement of high-density data center via two-phase liquid immersion cooling
    Mohammed, Nada M.
    El-Maghlany, Wael M.
    Elhelw, Mohamed
    Abdelaziz, Ahmed H.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [6] Enhancing high-density battery performance through innovative single-phase spray technology in immersion cooling systems
    Shi, Hong
    Zeng, Zhuo
    Kong, Benben
    Yuan, Nenglin
    JOURNAL OF POWER SOURCES, 2025, 626
  • [7] Performance evaluation and optimization of data center servers using single-phase immersion cooling
    Wang, Huijuan
    Yuan, Xuejun
    Zhang, Kun
    Lang, Xujin
    Chen, Hua
    Yu, Huimin
    Li, Shengtao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 221
  • [8] Study on the operation strategy of the water cooling system in the single-phase immersion cooling data center considering cooling tower performance
    Wang, Chenxu
    Yu, Hang
    Xian, Lei
    Liu, Guoqiu
    Chen, Lei
    Tao, Wen-Quan
    ENERGY AND BUILDINGS, 2024, 324
  • [9] Experimental study on the immersion liquid cooling performance of high-power data center servers
    Huang, Yongping
    Liu, Bin
    Xu, Shijie
    Bao, Chujin
    Zhong, Yangfan
    Zhang, Chengbin
    ENERGY, 2024, 297
  • [10] Computational study of single-phase immersion cooling for high-energy density server rack for data centers
    Kim, Jeebeom
    Choi, Hongseok
    Lee, Sangwook
    Lee, Hoseong
    APPLIED THERMAL ENGINEERING, 2025, 264