Design, construction, and commissioning of a 500 kW high-temperature heat pump plant for the district heating network of Bochum, Germany

被引:0
|
作者
Passamonti, Arianna [1 ,2 ]
Sachse, Frank [3 ]
Bombarda, Paola [4 ]
Bracke, Rolf [1 ,2 ]
机构
[1] Fraunhofer IEG, Fraunhofer Res Inst Energy Infrastruct & Geotherma, Breslauer Str 48, D-76139 Karlsruhe, Germany
[2] Ruhr Univ Bochum, Inst Energy Technol, Fac Mech Engn, Chair Geothermal Energy Syst, Univ Str 150, D-44801 Bochum, Germany
[3] Fraunhofer IEG, Fraunhofer Res Inst Energy Infrastruct & Geotherma, Kockerellstr 17, D-52062 Aachen, Germany
[4] Politecn Milan, Dipartimento Energia, Piazza Leonardo Vinci 32, I-20133 Milan, Italy
关键词
High-temperature heat pump; Pilot plant development; Mine thermal energy storage; CO; 2; reduction;
D O I
10.1016/j.egyr.2024.11.080
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An innovative thermal pilot plant at the Fraunhofer IEG location in Bochum is a proof of concept for the technical use of high-temperature heat pumps (HTHPs) with seasonal mine thermal energy storages (MTESs), as a heat source, to supply conventional district heating grids (DHGs), significantly lowering CO2 emissions from fossil fuel employment. In this study, we present the steps involved in plant development, from preparation and planning to construction, testing and heat injection, which were essential for achieving successful operation and advancing the plant from TRL 4 to TRL 8. The implementation phases enabled the injection of heat into the DH grid, currently allowing to save annually up to 4800 tons of CO2 emissions, and represent a solid base for the construction of analogous experimental systems, which will be increasingly required due to greenhouse gas emissions reduction and renewable energy implementation. An important technological accomplishment of the project is the first-time achievement of the HTHP, which features a cascaded system of two units with ammonia and butane as refrigerants, of a supply temperature of 120 degrees C. The plant technology can be transferred and scaled to various applications, including industrial processes and low-temperature DHGs, and locations. Given the abundance of unused mining facilities and high thermal energy needs in these regions, the system can be implemented in former mining areas and paired with other geothermal sources. Depending on the available MTES, various HTHP sizes can be considered, ranging from tens of MW to smaller than the installed one.
引用
收藏
页码:548 / 561
页数:14
相关论文
共 50 条
  • [21] A high-temperature heat pump for compressed heat energy storage applications: Design, modeling, and performance
    Hassan, Abdelrahman H.
    Corberan, Jose M.
    Ramirez, Miguel
    Trebilcock-Kelly, Felipe
    Paya, Jorge
    ENERGY REPORTS, 2022, 8 : 10833 - 10848
  • [22] Ammonia-based hybrid chemisorption-compression heat pump for high-temperature heating
    Xie, Xiangyu
    Jin, Shengxiang
    Gao, Peng
    Wu, Weidong
    Yang, Qiguo
    Wang, Liwei
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [23] THERMAL PERFORMANCE OF A GEOTHERMAL SOURCE HIGH-TEMPERATURE HEAT PUMP FOR DISTRICT HEATING - COMPARISON OF SINGLE-STAGE AND CASCADE VAPOR COMPRESSION CYCLES
    Dickinson, Devon
    Mai, An
    Govedarica, Aleksandra
    Shor, Roman
    Mwesigye, Aggrey
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 7, 2023,
  • [24] Influence of supply temperature and booster technology on the energetic performance and levelized cost of heat of a district heating network with central heat pump
    Degelin, A.
    Tassenoy, R.
    Vieren, E.
    Demeester, T.
    T'Jollyn, I.
    De Paepe, M.
    ENERGY, 2024, 312
  • [25] The Technology of High-temperature Reactors Design, Construction, Commissioning, Operation of the Julich AVR and the THTR-300
    Cleve, Urban
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2009, 54 (12): : 776 - +
  • [26] Interdisciplinary Design of a High-Speed Drivetrain for a Kinetic Compressor in a High-Temperature Heat Pump
    Kepsu, Daria
    Kurvinen, Emil
    Tiainen, Jonna
    Honkatukia, Juha
    Turunen-Saaresti, Teemu
    Jastrzebski, Rafal Piotr
    IEEE ACCESS, 2021, 9 : 143877 - 143900
  • [27] Investigation of the performance of a high-temperature heat pump using parallel cycles with serial heating on the water side
    Wang, Kai
    Cao, Feng
    Wang, Shouguo
    Xing, Ziwen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (06): : 1142 - 1151
  • [28] DESIGN, CONSTRUCTION AND OPERATION OF A HIGH-TEMPERATURE HOT BLAST STOVE FOR HEATING EXCLUSIVELY WITH BF GAS
    VOGES, B
    STAHL UND EISEN, 1983, 103 (19): : 951 - 956
  • [29] WASTE HEAT UTILIZATION FOR DISTRICT HEATING AT NUCLEAR-POWER STATIONS WITH HIGH-TEMPERATURE REACTOR AND HELIUM TURBINE
    BIELE, B
    BODE, KH
    FRUTSCHI, HU
    SCHNEIDER, KU
    BRENNSTOFF-WARME-KRAFT, 1979, 31 (03): : 89 - 94
  • [30] An optimal design method for a heat exchanger for a dual-stage circulating high-temperature heat pump system
    Zhao, Tianyi
    Zhang, Jili
    Ma, Liangdong
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 698 - 715