Ammonia-based hybrid chemisorption-compression heat pump for high-temperature heating

被引:6
|
作者
Xie, Xiangyu [1 ]
Jin, Shengxiang [1 ]
Gao, Peng [1 ]
Wu, Weidong [1 ]
Yang, Qiguo [1 ]
Wang, Liwei [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Shanghai Jiao Tong Univ, Key Lab Power Machinery & Engn, Minist Educ, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemisorption heat pump; Hybrid cycle; High-temperature heating; Regulation strategy; Waste heat recovery; WATER-VAPOR COMPRESSION; WASTE HEAT; SYSTEM; REFRIGERANTS; RECOVERY; STATE;
D O I
10.1016/j.applthermaleng.2023.121081
中图分类号
O414.1 [热力学];
学科分类号
摘要
Conventional compression heat pumps employing natural refrigerant of ammonia can barely meet the requirement of high-temperature heating above 90 & DEG;C, while ammonia-based chemisorption heat transformers characterised by high-temperature heating require driving heat source temperature above 80 & DEG;C. To address these issues, a novel ammonia-based hybrid chemisorption-compression high-temperature heat pump employing SrCl2NH3 as the working pair is designed and established in this paper. Particularly, a conventional normal temperature compressor instead of an expensive high-pressure ammonia compressor can be adopted to upgrade the abundant 50-80 & DEG;C waste heat to 90-120 & DEG;C high-temperature heat. Simultaneously, due to that chemisorption reaction heat is larger than condensing heat of refrigerant, this heat pump has significant potential for improving coefficient of performance (COP). For the first time, regulation strategies of key parameters such as sorption pressure, desorption pressure, and sorption reaction exothermic time are proposed, and these provide the theoretical support for the stable and efficient operation of the heat pump. Moreover, its performance is evaluated by varying operating conditions. The results indicate that at heat output temperature of 100 & DEG;C, the optimal sorption pressure and reaction exothermic time are 1.70 MPa and 22 min, respectively. At waste heat temperature of 70 & DEG;C and heat output temperature of 110 & DEG;C, the COP of the heat pump is 4.58, i.e., its efficiency is 14.5% more than that of R245fa compression one.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Ammonia-based chemisorption heat pumps for cold-climate heating applications: A comprehensive review
    Yang, Zhiyao
    Qu, Ming
    Gluesenkamp, Kyle R.
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [2] A high-temperature hybrid absorption-compression heat pump for waste heat recovery
    Liu, Changchun
    Jiang, Yingchun
    Han, Wei
    Kang, Qilan
    ENERGY CONVERSION AND MANAGEMENT, 2018, 172 : 391 - 401
  • [3] Investigation of a High-Temperature Heat Pump for Heating Purposes
    Bellos, Evangelos
    Tsimpoukis, Dimitrios
    Lykas, Panagiotis
    Kitsopoulou, Angeliki
    Korres, Dimitrios N.
    Vrachopoulos, Michail Gr.
    Tzivanidis, Christos
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [4] HIGH-TEMPERATURE HEAT PUMP INTEGRATION INTO DISTRICT HEATING SYSTEM
    Jakovleva, Ludmila
    20TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2021, : 1312 - 1316
  • [5] Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture
    Kim, Jiyoung
    Park, Seong-Ryong
    Baik, Young-Jin
    Chang, Ki-Chang
    Ra, Ho Sang
    Kim, Minsung
    Kim, Yongchan
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (12) : 1367 - 1373
  • [6] Experimental study of operating characteristics of compression/absorption high-temperature hybrid heat pump using waste heat
    Kim, Jiyoung
    Park, SeonZyong
    Baik, Young-Jin
    Chang, Ki-Chang
    Ra, Ho-Sang
    Kim, Minsung
    Kim, Yongchan
    RENEWABLE ENERGY, 2013, 54 : 13 - 19
  • [7] Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate
    Yang, Zhiyao
    Qu, Ming
    Gluesenkamp, Kyle R.
    ENERGY, 2020, 207
  • [8] PT and viscosity measurements of high-temperature ammonia heat pump lubricants
    Feja, S.
    Hanzelmann, C.
    Zuber, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 221 - 228
  • [9] Performance analysis of high temperature heat pump based on the hybrid compression of water medium
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1081 - 1090
  • [10] Study on ammonia/water hybrid absorption/compression heat pump cycle to produce high temperature process water
    Jung, Chung Woo
    Song, Joo Young
    Kang, Yong Tae
    ENERGY, 2018, 145 : 458 - 467