Thermometry in dynamic and high-temperature combustion filed based on hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

被引:0
|
作者
基于混合飞秒/皮秒相干反斯托克斯拉曼散射的动态高温燃烧场温度测量
机构
[1] Tian, Zi-Yang
[2] Zhao, Hui-Jie
[3] Wei, Hao-Yun
[4] Li, Yan
来源
Li, Yan (liyan@mail.tsinghua.edu.cn) | 1600年 / Institute of Physics, Chinese Academy of Sciences卷 / 70期
关键词
Raman spectroscopy - Coherent scattering - High temperature applications - Least squares approximations - Curve fitting - Raman scattering - Waste incineration - Carbon monoxide;
D O I
暂无
中图分类号
学科分类号
摘要
Temperature, as an important parameter in combustion diagnostic process, will directly affect the combustion efficiency and the generation of combustion products. The accurate measuring of combustion temperature and then controlling of combustion state can not only contribute to avoiding the generation of harmful waste gas, such as carbon monoxide (CO) and oxynitride (NOx), but also improve the combustion efficiency, thereby saving the energy. However, in practical applications, dynamic and high-temperature combustion field has strict requirements for measurement accuracy and response speed of the thermometry technology. As an advanced spectral thermometry technology, coherent anti-Stokes Raman scattering (CARS) has a much higher spatial resolution, and can achieve accurate temperature measurement in high-temperature environment, so CARS has the potential applications in complex combustion field. For the temperature measurement requirements in the complex dynamic and high-temperature combustion field, we demonstrate a hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering thermometry method through using the second harmonic bandwidth compression method, and achieve accurate measurements and dynamic response to temperature in dynamic and high-temperature combustion field. By using the narrow-band picosecond pulse obtained from the sum frequency process of femtosecond pulse in the BBO crystal as a probe pulse, this thermometry method can achieve single-shot, 1-kHz temperature measurement in high-temperature flame. We utilize the standard burner to simulate dynamic combustion field in a range of 1700-2200 K by changing the equivalence ratio quickly, and carry out continuous temperature measurement in 70 s by our thermometry method in this simulated dynamic and high-temperature flame. The least square method is used to fit the theoretical spectrum library to the actual single spectrum, and the fitting temperature corresponding to the actual single spectrum is obtained from the curve of fitting error. The continuous temperature measurements in 70 s exhibit superior performance in dynamic and high-temperature flame with a temperature inaccuracy less than 1.2% and a precision less than 1.8% at four different temperatures, and can track the temperature variation process within 0.2 s dynamically. These results verify the accuracy, stability and response speed in dynamic and high-temperature environment, and provide a new system scheme for thermometry in practical harsh combustion field. © 2021 Chinese Physical Society.
引用
收藏
相关论文
共 50 条
  • [41] ROTATIONAL COHERENT ANTI-STOKES RAMAN-SCATTERING FOR COMBUSTION RESEARCH
    MAGENS, E
    LEIPERTZ, A
    JOURNAL DE PHYSIQUE, 1987, 48 (C-7): : 772 - 772
  • [42] Femtosecond Coherent Anti-Stokes Raman Scattering Measurement of Gas-Phase Species and Temperature
    Lucht, Robert P.
    Kinnius, Paul J.
    Roy, Sukesh
    Gord, James R.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1469 - +
  • [43] APPLICATION OF COHERENT ANTI-STOKES RAMAN SCATTERING TO COMBUSTION MEDIA.
    Goss, Larry P.
    Switzer, Gary L.
    Technical Report AFWAL-TR - Air Force Wright Aeronautical Laboratories (United States), 1981,
  • [44] PICOSECOND COHERENT ANTI-STOKES RAMAN-SCATTERING OF EXCITED-STATES
    PAYNE, SA
    HOCHSTRASSER, RM
    JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (10): : 2068 - 2074
  • [45] COHERENT ANTI-STOKES RAMAN-SCATTERING IN GASEOUS NITROGEN WITH PICOSECOND PULSES
    GREENE, BI
    WEISMAN, RB
    HOCHSTRASSER, RM
    CHEMICAL PHYSICS LETTERS, 1978, 59 (01) : 5 - 9
  • [46] Quantum squeezing effects of radiation in Stokes and anti-Stokes modes in coherent anti-Stokes Raman scattering and coherent anti-Stokes hyper-Raman scattering
    Giri, DK
    Gupta, PS
    JOURNAL OF MODERN OPTICS, 2004, 51 (11) : 1705 - 1715
  • [47] STOKES AND ANTI-STOKES COHERENT RAMAN-SCATTERING
    CHANDRA, S
    COMPAAN, AD
    WIENERAVNEAR, E
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (03): : 315 - 315
  • [48] Coherent Anti-Stokes Raman Scattering Microscopy
    Cheng, Ji-Xin
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 2905 - 2906
  • [49] Compact fibre-based coherent anti-Stokes Raman scattering spectroscopy and interferometric coherent anti-Stokes Raman scattering from a single femtosecond fibre-laser oscillator
    Kumar, Vikas
    Gambetta, Alessio
    Manzoni, Cristian
    Ramponi, Roberta
    Cerullo, Giulio
    Marangoni, Marco
    PRAMANA-JOURNAL OF PHYSICS, 2010, 75 (06): : 1129 - 1134
  • [50] Compact fibre-based coherent anti-Stokes Raman scattering spectroscopy and interferometric coherent anti-Stokes Raman scattering from a single femtosecond fibre-laser oscillator
    Vikas Kumar
    Alessio Gambetta
    Cristian Manzoni
    Roberta Ramponi
    Giulio Cerullo
    Marco Marangoni
    Pramana, 2010, 75 : 1129 - 1134