Thermometry in dynamic and high-temperature combustion filed based on hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

被引:0
|
作者
基于混合飞秒/皮秒相干反斯托克斯拉曼散射的动态高温燃烧场温度测量
机构
[1] Tian, Zi-Yang
[2] Zhao, Hui-Jie
[3] Wei, Hao-Yun
[4] Li, Yan
来源
Li, Yan (liyan@mail.tsinghua.edu.cn) | 1600年 / Institute of Physics, Chinese Academy of Sciences卷 / 70期
关键词
Raman spectroscopy - Coherent scattering - High temperature applications - Least squares approximations - Curve fitting - Raman scattering - Waste incineration - Carbon monoxide;
D O I
暂无
中图分类号
学科分类号
摘要
Temperature, as an important parameter in combustion diagnostic process, will directly affect the combustion efficiency and the generation of combustion products. The accurate measuring of combustion temperature and then controlling of combustion state can not only contribute to avoiding the generation of harmful waste gas, such as carbon monoxide (CO) and oxynitride (NOx), but also improve the combustion efficiency, thereby saving the energy. However, in practical applications, dynamic and high-temperature combustion field has strict requirements for measurement accuracy and response speed of the thermometry technology. As an advanced spectral thermometry technology, coherent anti-Stokes Raman scattering (CARS) has a much higher spatial resolution, and can achieve accurate temperature measurement in high-temperature environment, so CARS has the potential applications in complex combustion field. For the temperature measurement requirements in the complex dynamic and high-temperature combustion field, we demonstrate a hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering thermometry method through using the second harmonic bandwidth compression method, and achieve accurate measurements and dynamic response to temperature in dynamic and high-temperature combustion field. By using the narrow-band picosecond pulse obtained from the sum frequency process of femtosecond pulse in the BBO crystal as a probe pulse, this thermometry method can achieve single-shot, 1-kHz temperature measurement in high-temperature flame. We utilize the standard burner to simulate dynamic combustion field in a range of 1700-2200 K by changing the equivalence ratio quickly, and carry out continuous temperature measurement in 70 s by our thermometry method in this simulated dynamic and high-temperature flame. The least square method is used to fit the theoretical spectrum library to the actual single spectrum, and the fitting temperature corresponding to the actual single spectrum is obtained from the curve of fitting error. The continuous temperature measurements in 70 s exhibit superior performance in dynamic and high-temperature flame with a temperature inaccuracy less than 1.2% and a precision less than 1.8% at four different temperatures, and can track the temperature variation process within 0.2 s dynamically. These results verify the accuracy, stability and response speed in dynamic and high-temperature environment, and provide a new system scheme for thermometry in practical harsh combustion field. © 2021 Chinese Physical Society.
引用
收藏
相关论文
共 50 条
  • [21] A femtosecond time-resolved coherent anti-Stokes Raman spectroscopy thermometry for steady-state high-temperature flame
    Song, Yunfei
    Wu, Honglin
    Zhu, Gangbei
    Zeng, Yangyang
    Yu, Guoyang
    Yang, Yanqiang
    COMBUSTION AND FLAME, 2022, 242
  • [22] Interference-free gas-phase thermometry at elevated pressure using hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering
    Miller, Joseph D.
    Dedic, Chloe E.
    Roy, Sukesh
    Gord, James R.
    Meyer, Terrence R.
    OPTICS EXPRESS, 2012, 20 (05): : 5003 - 5010
  • [23] Single-shot gas-phase thermometry using pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering
    Miller, Joseph D.
    Roy, Sukesh
    Slipchenko, Mikhail N.
    Gord, James R.
    Meyer, Terrence R.
    OPTICS EXPRESS, 2011, 19 (16): : 15627 - 15640
  • [24] Hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering temperature and concentration measurements using two different picosecond-duration probes
    Kearney, Sean P.
    Scoglietti, Daniel J.
    Kliewer, Christopher J.
    OPTICS EXPRESS, 2013, 21 (10): : 12327 - 12339
  • [25] Spatially multiplexed femtosecond/picosecond coherent anti-Stokes Raman scattering for multipoint array measurements
    Braun, Erik L.
    Slipchenko, Mikhail N.
    Roy, Sukesh
    Meyer, Terrence R.
    OPTICS LETTERS, 2022, 47 (20) : 5280 - 5283
  • [26] Technique developments and performance analysis of chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering combustion thermometry
    Thomas, Levi M.
    Satija, Aman
    Lucht, Robert P.
    APPLIED OPTICS, 2017, 56 (31) : 8797 - 8810
  • [27] Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen a high pressures and temperatures
    Mecker, Nils Torge
    Courtney, Trevor L.
    Patterson, Brian D.
    Escofet-Martin, David
    Peterson, Brian
    Kliewer, Christopher J.
    Linne, Mark
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2020, 37 (04) : 1035 - 1046
  • [28] Coherent Anti-Stokes Raman Scattering Thermometry Applied to a Supersonic Combustor
    Zhang, Li-rong
    Hu, Zhi-yun
    Ye, Jing-feng
    Zhang, Zhen-rong
    Wang, Sheng
    Liu, Jing-ru
    2ND INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER (LIMIS 2012), 2013, 8796
  • [29] Dual-pump vibrational/rotational femtosecond/picosecond coherent anti-Stokes Raman scattering temperature and species measurements
    Dedic, Chloe E.
    Miller, Joseph D.
    Meyer, Terrence R.
    OPTICS LETTERS, 2014, 39 (23) : 6608 - 6611
  • [30] Two-beam femtosecond coherent anti-Stokes Raman scattering for thermometry on CO2
    Kerstan, M.
    Makos, I.
    Nolte, S.
    Tuennermann, A.
    Ackermann, R.
    APPLIED PHYSICS LETTERS, 2017, 110 (02)