Experiment and design improvement of an axial flow blood pump

被引:0
|
作者
School of Jet Propulsion, Beijing University of Aeronautics and Astronautics, Beijing 100083, China [1 ]
不详 [2 ]
机构
来源
Hangkong Dongli Xuebao | 2008年 / 6卷 / 1061-1066期
关键词
Flow separation - Shear stress - Shear flow - Diseases - Pumps - Blood - Blood vessels - Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
The numerical investigation and experimental results of the proto-pump LAP-00 show that at design rotational speed of 9000 r/min, the flow rate corresponding to the highest efficiency point is 11 L/min, which is much higher than clinical use (3-8 L/min), causing the pump to work at off design point in clinic use with a low efficiency. Besides, in the diffuser region, flow separation and recirculation may cause blood stagnation and thrombosis. The improved design for pump LAP-23 decreases the design rotational speed from 9000 r/min to 8000 r/min, thus reduces the high shear stress on blood cells at impeller tip; meanwhile, it decreases the design flow rate to 6 L/min and eliminates flow separation and recirculation in the diffuser region.
引用
收藏
相关论文
共 50 条
  • [31] Design of a Protective Cage for an Intravascular Axial Flow Blood Pump to Mechanically Assist the Failing Fontan
    Throckmorton, Amy L.
    Kishore, Ravi A.
    ARTIFICIAL ORGANS, 2009, 33 (08) : 611 - 621
  • [32] A Controller Design for an Axial Flow Blood Pump Based on Back-EMF without Delay
    Gao, Bin
    Song, Miao
    Chang, Yu
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1242 - 1245
  • [33] Axial type self-bearing motor for axial flow blood pump
    Okada, Y
    Masuzawa, T
    Matsuda, KI
    Ohmori, K
    Yamane, T
    Konishi, Y
    Fukahori, S
    Ueno, S
    Kim, SJ
    ARTIFICIAL ORGANS, 2003, 27 (10) : 887 - 891
  • [34] Performance prediction and experiment for pressure fluctuation of interior flow in axial-flow pump
    Shi, Weidong
    Leng, Hongfei
    Zhang, Desheng
    Long, Fei
    Zhang, Hua
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2011, 42 (05): : 44 - 48
  • [35] Numerical investigation on flow field and biocompatibility of an axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Liu, Haonan
    Zhang, Genguang
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2006, 40 (11): : 1290 - 1294
  • [36] Discrete-continuous optimisation of an axial flow blood pump
    Tesch, K.
    Kaczorowska-Ditrich, K.
    XXIII FLUID MECHANICS CONFERENCE (KKMP 2018), 2018, 1101
  • [37] A mechanically non-contact axial flow blood pump
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 878 - 878
  • [38] Study on control parameters in the acceleration of axial flow blood pump
    Xie Xiong
    Tan Jianping
    Liu Hengtuo
    Liu Yunlong
    Tan Wei
    Tan Zhuo
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 1031 - 1034
  • [40] Numerical Simulation Investigation on Flow Field of Axial Blood Pump
    Zhang, Lu
    Jia, Yuemei
    Zhang, Wei
    Wang, Yuxuan
    Zhao, Qiuxia
    ADVANCES IN COMPUTER SCIENCE AND ENGINEERING, 2012, 141 : 223 - +