Performance evaluation of high-volume evacuation for removing droplets during dental treatment

被引:1
|
作者
Xing, Chaojie [1 ,2 ]
Ai, Zhengtao [1 ,2 ]
Mak, Cheuk Ming [3 ]
Wong, Hai Ming [4 ]
机构
[1] Hunan Univ, Dept Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Natl Ctr Int Res Collaborat Bldg Safety & Environm, Changsha, Hunan, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hung Hom, Hong Kong, Peoples R China
[4] Univ Hong Kong, Fac Dent, Pok Fu Lam, Hong Kong, Peoples R China
关键词
high-volume evacuation (HVE); ultrasonic scaling instruments (USI); powder jet handpieces (PJH); high-speed air turbine handpiece (HATH); fallow time (FT); computational fluid dynamics (CFD); BACTERIAL AEROSOLS; REDUCTION; PARTICLES; EFFICACY; DYNAMICS; DEVICE; SALIVA;
D O I
10.1007/s12273-024-1187-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
The high-volume evacuation (HVE) is commonly employed as a primary source control measure for removing splatter emitted from mouth during dental treatments, but there is still a lack of comprehensive understanding of its efficiency. Based on our previous experiments on the emission characteristics during dental treatments, this study employed computational fluid dynamics (CFD) simulations to investigate the impact of emission parameters (droplet size, emission velocity, emission angle), HVE usage methods (distance between HVE and the droplet release source), and HVE suction flow rates on its removal efficiency. The effect of HVE on fallow time (FT) was also examined. Cumulative removal efficiency that accurately reflected the HVE effect was proposed as an evaluation index. It was found that emission velocity and distance between HVE and the source were key factors determining cumulative removal efficiency. When the distance was 4 cm, the cumulative removal efficiencies for low-velocity (0.8 m/s), medium-velocity (3.4 m/s), and high-velocity droplets (6.0 m/s) were approximately 97.9%, 73.6%, and 58.0%, respectively. For high-velocity droplets at 6.0 m/s, decreasing the distance from 4 cm to 2 cm and 1 cm increased the cumulative removal efficiency from 58.0% to 76.7% and 100%. This study was expected to enhance the understanding of HVE performance and provide information on its usage method. It also indicated the need for developing advanced control measures that could have high efficiency in removing both low-velocity and high-velocity droplets.
引用
收藏
页码:2263 / 2280
页数:18
相关论文
共 50 条
  • [41] The Survival Impact of Treatment at High-Volume Facilities for Nasopharyngeal Carcinoma
    Yoshida, E. J.
    Ho, A. S.
    Shiao, S. L.
    David, J.
    Mita, A.
    Scher, K.
    Zumsteg, Z. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E384 - E384
  • [42] Surgical treatment of GIST - An institutional experience of a high-volume center
    Schwameis, Katrin
    Fochtmann, Alexandra
    Schwameis, Michael
    Asari, Reza
    Schur, Sophie
    Koestler, Wolfgang
    Birner, Peter
    Ba-Ssalamah, Ahmed
    Zacherl, Johannes
    Wrba, Fritz
    Brodowicz, Thomas
    Schoppmann, Sebastian Friedrich
    INTERNATIONAL JOURNAL OF SURGERY, 2013, 11 (09) : 801 - 806
  • [43] PERFORMANCE TESTING IN OXYGEN OF A HIGH-PRESSURE, HIGH-VOLUME OXYGEN COMPRESSOR
    TESSIER, MJ
    GRANGER, RA
    MECHANICAL ENGINEERING, 1983, 105 (11) : 104 - 104
  • [44] High-performance, high-volume fly ash concrete for sustainable development
    Mehta, PK
    PROCEEDINGS OF THE INTERNATIONAL WORKSHOP ON SUSTAINABLE DEVELOPMENT AND CONCRETE TECHNOLOGY, 2004, : 3 - 14
  • [45] Training for intense exercise performance: high-intensity or high-volume training?
    Laursen, P. B.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2010, 20 : 1 - 10
  • [46] Mental Fatigue Evaluation of Surgical Teams during a Regular Workday in a High-Volume Tertiary Healthcare Center
    Petrut, Bogdan
    Berindan-Neagoe, Ioana
    Feflea, Dragos, I
    Hogea, Maximilian
    Pasca, Sergiu
    Bujoreanu, Cristina E.
    Bschleipfer, Thomas
    UROLOGIA INTERNATIONALIS, 2020, 104 (3-4) : 301 - 308
  • [47] HIGH-VOLUME, HIGH-PRESSURE PULSATILE LAVAGE DURING CEMENTED ARTHROPLASTY
    BYRICK, RJ
    BELL, RS
    KAY, JC
    WADDELL, JP
    MULLEN, JB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (09): : 1331 - 1336
  • [48] Optimizing high-volume evacuator usage: A quantitative analysis of aerosol control in dental procedures
    Song, Chenxue
    Zheng, Xiaohong
    Han, Lei
    Wan, Qinjie
    Huang, Jiayu
    Ding, Zhen
    Qian, Hua
    BUILDING AND ENVIRONMENT, 2025, 269
  • [49] Evaluation of the long-term performance of high-performance concrete produced with blended river sand/sea sand and high-volume GGBFS
    Vo, Duy-Hai
    Doan, Vinh-Phuc
    Nguyen, May Huu
    Nguyen, Tan-Khoa
    JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2024, 26 (04) : 2393 - 2412
  • [50] Performance of High-Volume Fly Ash Concrete Incorporating Lime Water
    Gunasekera, C.
    Ling, X. H.
    Setunge, S.
    Law, D. W.
    Patnaikuni, I
    ACI MATERIALS JOURNAL, 2018, 115 (02) : 289 - 297