Performance evaluation of high-volume evacuation for removing droplets during dental treatment

被引:1
|
作者
Xing, Chaojie [1 ,2 ]
Ai, Zhengtao [1 ,2 ]
Mak, Cheuk Ming [3 ]
Wong, Hai Ming [4 ]
机构
[1] Hunan Univ, Dept Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Natl Ctr Int Res Collaborat Bldg Safety & Environm, Changsha, Hunan, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hung Hom, Hong Kong, Peoples R China
[4] Univ Hong Kong, Fac Dent, Pok Fu Lam, Hong Kong, Peoples R China
关键词
high-volume evacuation (HVE); ultrasonic scaling instruments (USI); powder jet handpieces (PJH); high-speed air turbine handpiece (HATH); fallow time (FT); computational fluid dynamics (CFD); BACTERIAL AEROSOLS; REDUCTION; PARTICLES; EFFICACY; DYNAMICS; DEVICE; SALIVA;
D O I
10.1007/s12273-024-1187-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
The high-volume evacuation (HVE) is commonly employed as a primary source control measure for removing splatter emitted from mouth during dental treatments, but there is still a lack of comprehensive understanding of its efficiency. Based on our previous experiments on the emission characteristics during dental treatments, this study employed computational fluid dynamics (CFD) simulations to investigate the impact of emission parameters (droplet size, emission velocity, emission angle), HVE usage methods (distance between HVE and the droplet release source), and HVE suction flow rates on its removal efficiency. The effect of HVE on fallow time (FT) was also examined. Cumulative removal efficiency that accurately reflected the HVE effect was proposed as an evaluation index. It was found that emission velocity and distance between HVE and the source were key factors determining cumulative removal efficiency. When the distance was 4 cm, the cumulative removal efficiencies for low-velocity (0.8 m/s), medium-velocity (3.4 m/s), and high-velocity droplets (6.0 m/s) were approximately 97.9%, 73.6%, and 58.0%, respectively. For high-velocity droplets at 6.0 m/s, decreasing the distance from 4 cm to 2 cm and 1 cm increased the cumulative removal efficiency from 58.0% to 76.7% and 100%. This study was expected to enhance the understanding of HVE performance and provide information on its usage method. It also indicated the need for developing advanced control measures that could have high efficiency in removing both low-velocity and high-velocity droplets.
引用
收藏
页码:2263 / 2280
页数:18
相关论文
共 50 条
  • [21] Evaluation of miniature and high-volume bioassays for screening insecticides
    Jansson, RK
    Halliday, WR
    Argentine, JA
    JOURNAL OF ECONOMIC ENTOMOLOGY, 1997, 90 (06) : 1500 - 1507
  • [22] FORMATION OF NITROARENES DURING AMBIENT HIGH-VOLUME SAMPLING
    AREY, J
    ZIELINSKA, B
    ATKINSON, R
    WINER, AM
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (04) : 457 - 462
  • [23] RESULTS OF TREATMENT OF MORBID OBESITY IN A HIGH-VOLUME CENTER
    Emous, M.
    Apers, J.
    Hoff, C.
    Totte, E.
    OBESITY SURGERY, 2012, 22 (08) : 1151 - 1151
  • [24] THE TREATMENT OF HIGH-VOLUME TESTICULAR CANCER - A PERSISTING DILEMMA
    VANOOSTEROM, AT
    ANNALS OF ONCOLOGY, 1992, 3 (04) : 256 - 256
  • [25] High-volume spray aerosol generator producing small droplets for low pressure applications
    Kang, Y.C.
    Park, S.B.
    Journal of Aerosol Science, 1995, 26 (07):
  • [26] Surgical treatment of pNET - Experience of a "high-volume" center
    Boesch, Florian
    Hofmann, Katharina
    Coenen, Michaela
    Pratschke, Sebastian
    Thomas, Michael
    Knoesel, Thomas
    Bruns, Christiane J.
    Guba, Markus
    Werner, Jens
    Angele, Martin K.
    SURGICAL ONCOLOGY-OXFORD, 2018, 27 (03): : 409 - 414
  • [27] Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence
    Shaikh, M. S.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (02) : 193 - 197
  • [28] ANALYTICAL PERFORMANCE EVALUATION OF A HIGH-VOLUME HEMATOLOGY LABORATORY UTILIZING SIGMA METRICS AS STANDARD OF EXCELLENCE
    Shaikh, Muhammad Shariq
    Moiz, Bushra
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 94 - 94
  • [29] A High-Performance Reflector Antenna Appropriate for High-Volume Production
    Fleming, Matthew C.
    Lacy, Gordon E.
    Baker, Lynn
    Byrnes, Peter
    Cortes-Medellin, German
    DeBoer, David R.
    Fitzsimmons, Joeleff
    Hellyer, Richard
    Hovey, Gary
    Imbriale, William
    Veidt, Bruce
    2013 US NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2013,
  • [30] Spray mist reduction by means of a high-volume evacuation system-Results of an experimental study
    Koch, Martin