Seismic demand-oriented design of hybrid base-isolated building with the tuned inerter eddy current damper

被引:2
|
作者
Li, Dawei [1 ,2 ]
Bai, He [1 ]
Lou, Yu [2 ]
Han, Jianping [1 ]
机构
[1] Lanzhou Univ Technol, Sch Civil Engn, Lanzhou 730050, Peoples R China
[2] China Elect Engn Design Inst Co Ltd, Beijing 100142, Peoples R China
关键词
Base isolation system; Tuned inerter eddy current damper; Inerter; Nonlinear damping; Optimal design; MASS DAMPERS; VIBRATION CONTROL; IMPACT RESPONSE; PERFORMANCE;
D O I
10.1016/j.soildyn.2024.109068
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A novel tuned inerter eddy current damper (TIECD) is proposed to mitigate isolator deformation in a base isolation (BI) system subjected to earthquake ground motions. Considering the topological similarity and damping equivalent criteria, the design formulations of the tuned inerter damper are extended to determine the optimal parameters of the TIECD. A combination of iterative updating, response-spectrum analysis, and complex complete quadratic-combination measures is established to realize the seismic demand-oriented design framework of the TIECD. Furthermore, the proposed design framework incorporates the equivalent stiffness and damping of a lead rubber bearing to approximate the design parameters of the TIECD in a nonlinear BI system. Finally, the feasibility and effectiveness of the designed TIECD are validated using a nine-story base isolated benchmark model with lead rubber bearings. Numerical simulation results indicate that the designed TIECD can significantly suppress the displacement, acceleration, and base shear demands of the hybrid BI system. Compared with the viscous damping in the tuned inerter damper, the designed TIECD exhibits a significantly enhanced level of damping owing to the combination of a lower damping force and a larger deformation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Optimal design and seismic performance of base-isolated storage tanks using friction pendulum inerter systems
    Zhang, Li
    Guo, Ming
    li, Zhe
    Zhu, Lijie
    Meng, Yaolin
    STRUCTURES, 2022, 43 : 234 - 248
  • [32] Optimum design for more effective tuned mass damper system and its application to base-isolated buildings
    Xiang, P.
    Nishitani, A.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (01): : 98 - 114
  • [33] Smart structures through nontraditional design of Tuned Mass Damper Inerter for higher control of base isolated systems
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    MECHANICS RESEARCH COMMUNICATIONS, 2020, 105
  • [34] Experimental Assessment of the Seismic Response of a Base-Isolated Building Through a Hybrid Simulation Technique
    Furinghetti, Marco
    Lanese, Igor
    Pavese, Alberto
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [35] Hybrid system of base-isolated structures with tuned tandem mass damper-inerters considering internal friction
    Li, Xin
    Wang, Zhihao
    Pan, Hang
    Cao, Liyuan
    Li, Chunxiang
    JOURNAL OF BUILDING ENGINEERING, 2025, 101
  • [36] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Alberto Di Matteo
    Thomas Furtmüller
    Christoph Adam
    Antonina Pirrotta
    Acta Mechanica, 2018, 229 : 437 - 454
  • [37] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Di Matteo, Alberto
    Furtmueller, Thomas
    Adam, Christoph
    Pirrotta, Antonina
    ACTA MECHANICA, 2018, 229 (02) : 437 - 454
  • [38] Development of a Hybrid Base Isolation-Tuned Mass Damper Inerter System (BI-TMDI) for Seismic Protection of Steel Structures
    Bian, Jing
    Wang, Lin
    Ke, Ke
    Chen, Yonghui
    Chen, Lingyang
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 685 - 691
  • [39] Semi-Active Fuzzy Control of Tuned Mass Damper to Reduce Base-Isolated Building Response under Harmonic Excitation
    Djedoui, Nassim
    Ounis, Abdelhafid
    Mahdi, Abdeddaim
    Zahrai, Seyed Mehdi
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2018, 12 (03) : 435 - 448
  • [40] Mechanism of response reduction in hybrid control system of base-isolated building connected to free-wall with damper
    Hayashi K.
    Mitsuda E.
    Fujita K.
    Tsuji M.
    Takewaki I.
    Journal of Structural and Construction Engineering, 2017, 82 (737): : 1023 - 1033