Mechanism of response reduction in hybrid control system of base-isolated building connected to free-wall with damper

被引:0
|
作者
Hayashi K. [1 ]
Mitsuda E. [1 ]
Fujita K. [1 ]
Tsuji M. [1 ]
Takewaki I. [1 ]
机构
[1] Dept. of Architecture and Architectural Eng., Kyoto Univ.
来源
基金
日本学术振兴会;
关键词
Bas-isolation; Building connection for control; Complex eigenvalue analysis; Damping property; Eigenvibration; Robustness;
D O I
10.3130/aijs.82.1023
中图分类号
学科分类号
摘要
It is recognized that a base-isolated building exhibits a large response to a long-duration, long-period ground motion and an interconnected building system is not necessarily effective for a pulse-type ground motion. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is shown that the mechanism of response reduction in the proposed hybrid passive control system is closely related to the property of natural frequency and damping ratio with respect to increased capacity of connected dampers in a translation mode and a meeting-parting mode. © 2017 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:1023 / 1033
页数:10
相关论文
共 29 条
  • [1] Development of friction damper with coupling mechanism for displacement control of base-isolated system
    Zou, Shuang
    Ikenaga, Masahiro
    Hori, Norio
    Ikago, Kohju
    Inoue, Norio
    AIJ Journal of Technology and Design, 2013, 19 (43) : 855 - 860
  • [2] Semi-active seismic response control of base-isolated building with MR damper
    Soda, S
    Kusumoto, H
    Chatani, R
    Iwata, N
    Fujitani, H
    Shiozaki, Y
    Hiwatashi, T
    SMART STRUCTURES AND MATERIALS 2003: DAMPING AND ISOLATION, 2003, 5052 : 460 - 467
  • [3] Seismic response control of base-isolated structures with fluid inerter damper
    Akhare, Ashish R.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2023, 13 (01) : 1 - 21
  • [4] Seismic response control of base-isolated buildings using tuned mass damper
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Matsagar, Vasant A.
    Jain, Arvind K.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2020, 21 (01) : 310 - 321
  • [5] RESPONSE CONTROL of BASE-ISOLATED STRUCTURE INCORPORATED with A VISCOELASTICALLY SUPPORTED VISCOUS MASS DAMPER
    Kikuchi, Junya
    Ikenaga, Masahiro
    Ikago, Kohju
    Inoue, Norio
    Journal of Structural and Construction Engineering, 2015, 80 (716): : 1515 - 1524
  • [6] Assessment of the tuned mass damper inerter for seismic response control of base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02):
  • [7] System identification of base-isolated building using seismic response data
    Furukawa, T
    Ito, M
    Izawa, K
    Noori, MN
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2005, 131 (03): : 268 - 275
  • [8] Semi-Active Fuzzy Control of Tuned Mass Damper to Reduce Base-Isolated Building Response under Harmonic Excitation
    Djedoui, Nassim
    Ounis, Abdelhafid
    Mahdi, Abdeddaim
    Zahrai, Seyed Mehdi
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2018, 12 (03) : 435 - 448
  • [9] Experimental Assessment of the Seismic Response of a Base-Isolated Building Through a Hybrid Simulation Technique
    Furinghetti, Marco
    Lanese, Igor
    Pavese, Alberto
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [10] Optimization of base-isolated structure with negative stiffness tuned inerter damper targeting seismic response reduction
    Irakoze, Jean Paul
    Li, Shujin
    Pu, Wuchuan
    Nyangi, Patrice
    Sibomana, Amedee
    EARTHQUAKES AND STRUCTURES, 2023, 25 (06) : 399 - 415