Mechanism of response reduction in hybrid control system of base-isolated building connected to free-wall with damper

被引:0
|
作者
Hayashi K. [1 ]
Mitsuda E. [1 ]
Fujita K. [1 ]
Tsuji M. [1 ]
Takewaki I. [1 ]
机构
[1] Dept. of Architecture and Architectural Eng., Kyoto Univ.
来源
基金
日本学术振兴会;
关键词
Bas-isolation; Building connection for control; Complex eigenvalue analysis; Damping property; Eigenvibration; Robustness;
D O I
10.3130/aijs.82.1023
中图分类号
学科分类号
摘要
It is recognized that a base-isolated building exhibits a large response to a long-duration, long-period ground motion and an interconnected building system is not necessarily effective for a pulse-type ground motion. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is shown that the mechanism of response reduction in the proposed hybrid passive control system is closely related to the property of natural frequency and damping ratio with respect to increased capacity of connected dampers in a translation mode and a meeting-parting mode. © 2017 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:1023 / 1033
页数:10
相关论文
共 29 条
  • [21] Vibration Control of a Two-Story Base-Isolated Building using a New Tuned Mass Multi-Sliding Friction Damper
    Amjadian, Mohsen
    Haider, Syed Muhammad Bilal
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS XVII, 2023, 12483
  • [22] Seismic response control of multi-story base-isolated buildings using a smart electromagnetic friction damper with smooth hysteretic behavior
    Amjadian, Mohsen
    Agrawal, Anil K.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 130 : 409 - 432
  • [23] Experimental evaluation of a servomechanism-based PI controller for seismic response control in smart base-isolated steel building
    Panda, Jagajyoti
    Chakraborty, Sanjukta
    Ray-Chaudhuri, Samit
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 227
  • [24] Output feedback-based adaptive fuzzy sliding mode control for seismic response reduction of base-isolated buildings
    Rahmani, Behrooz
    Ziaiefar, Ali
    Hashemi, Shamsedin
    ISA TRANSACTIONS, 2022, 126 : 94 - 108
  • [25] Use of Simplified Nonlinear Response History Analysis to Inform Equivalent Lateral Force Procedure: A Hybrid Approach to Base-Isolated Building Design
    Wray, Gordon
    Sinclair, Mark
    Pedersen, Dallin
    Maxfield, Brent
    Moore, Erik
    STRUCTURES CONGRESS 2015, 2015, : 2532 - 2544
  • [26] A hybrid structural control system using a tuned liquid damper to reduce the wind induced motion of a base isolated structure
    Love, J. S.
    Tait, M. J.
    Toopchi-Nezhad, H.
    ENGINEERING STRUCTURES, 2011, 33 (03) : 738 - 746
  • [27] Reduction to single degree of freedom system of simple modeling method for lateral resistance of retaining wall with backfill soil in collision with base-isolated structure
    Inubushi T.
    Enomoto T.
    Journal of Structural and Construction Engineering, 2021, 86 (783): : 717 - 726
  • [28] Verification of real-time hybrid tests of response control of base isolation system by MR damper comparing shaking table tests
    Fujitani, Hideo
    Sakae, Hiroaki
    Kawasaki, Rui
    Fujii, Hideki
    Hiwatashi, Takeshi
    Saito, Taiki
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2008, PTS 1 AND 2, 2008, 6932
  • [29] Earthquake response reduction of mid-story isolated system due to semi-active control using magnetorheological rotary inertia mass damper
    Ito, Mai
    Yoshida, Shohei
    Fujitani, Hideo
    Sato, Yusuke
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2015, 2015, 9431