Feeder clamps for overhead contact lines

被引:0
|
作者
Biesenack, Hartmut [1 ]
Dölling, André [1 ]
Schmieder, Axel [2 ]
机构
[1] TU Dresden, Fakultät Verkehrswissen-schaften Friedrich List, Institut für Elektrische Verkehrssysteme, Hettnerstr. 1-3, 01069 Dresden, Germany
[2] Siemens AG, TS EL EN, Postfach 3240, 91050 Erlangen, Germany
来源
eb - Elektrische Bahnen | 2006年 / 104卷 / 07期
关键词
Bolted joints - Current limiting reactors - Electric conductors - Electric power systems;
D O I
暂无
中图分类号
学科分类号
摘要
Bolted as well as compressed current-carrying connections are used in overhead contact line installations. While compressed connections are aging to a low extent only, aging can change the characteristics of bolted connections significantly. The tightening force of bolts, the connection resistance, the Joule's heat and the surface conditions of the connected conductors establish the most important impact parameters. When replacing bolted clamps in existing installations the connecting conductors should be replaced as well. Heat cycle tests according to DIN EN 61284 are suited to assess the correct design of feeder clamps but not to forecast their long-term aging behaviour.
引用
收藏
页码:336 / 343
相关论文
共 50 条
  • [41] OVERHEAD LINES
    JANSEN, J
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1978, 99 (12): : 726 - 727
  • [42] Overhead lines
    Jeffers, D
    POWER ENGINEER, 2004, 18 (03): : 47 - 47
  • [43] Monitoring the Intensity of Ice Formation on Overhead Electric Power Lines and Contact Networks
    Titov D.E.
    Ugarov G.G.
    Soshinov A.G.
    Power Technology and Engineering, 2015, 49 (1) : 78 - 82
  • [44] Determination of Capacitive Couplings between Multiwire Overhead Contact System and Adjacent Lines
    Semenov, Yuriy
    Bodrov, Pavel
    Popova, Natalia
    2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,
  • [45] A Power Quality Case Study of Contact Overhead Lines in the Medellin Metro System
    Emiro Diez, Andres
    Restrepo, Mauricio
    Vega, Julian
    Melendez, Camilo
    Dariel Arcila, Jose
    Manrique, Edison
    2019 IEEE WORKSHOP ON POWER ELECTRONICS AND POWER QUALITY APPLICATIONS (PEPQA), 2019,
  • [46] The smart current collector - A tool for monitoring mechanical faults on overhead contact lines
    Schröder, Kerstin
    Ecke, Wolfgang
    Willett, Simon
    Österreich, Linz
    Jenzer, Matthias
    ZEVrail, 2009, 133 (08): : 292 - 301
  • [47] RECOLLECTIONS OF OVERHEAD LINES
    BUTCHER, H
    ELECTRONICS AND POWER, 1969, 15 (MAY): : 177 - &
  • [48] OVERHEAD LINES FOR SUPERGRID
    READING, AG
    ELECTRONICS AND POWER, 1973, 19 (15): : 352 - 356
  • [49] INSULATED OVERHEAD LINES
    SOARES, CG
    BONFA, AR
    TARALLI, C
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 2273 - 2277
  • [50] RECOLLECTIONS OF OVERHEAD LINES
    ASHBY, EW
    HAWLEY, WG
    ELECTRONICS AND POWER, 1969, 15 (JAN): : 26 - &